Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROSE MILL COMPANY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROSE MILL COMPANY, LLC in 100 BROOK STREET, WEST HARTFORD, CT 06110 (NAICS 325180). OSHA activity number 348478470.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rose Mill Company, LLC — free Get an email when a new federal OSHA severe-injury report for Rose Mill Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
100 BROOK STREET
City
WEST HARTFORD
State
CT
ZIP
06110
Mailing
100 BROOK STREET, WEST HARTFORD, CT 06110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325180
Employees
14
Ownership type
A

14 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2026
Penalty
Initial $2,270 · Current $1,589 Reduced
29 CFR  1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  Ribbon Blender:  On, or about, September 3, 2025, standard guardrails, or the equivalent, had not been provided on the open sides of the elevated work platform.
Recent events (2)
  • — I (S) $1589
  • — Z (S) $2270

1910.28 B11 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.28(b)(11)(i):29 CFR 1910.28(b)(11)(i):   The employer did not ensure that each employee exposed to an unprotected side or edge of a stairway landing that is 4 feet (1.2 m) or more above a lower level is protected by a guardrail or stair rail system:  Ribbon Blender:  On, or about, September 3, 2025, a railing had not been provided on the right side, ascending, of the upper landing on the access stairs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B11 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.28(b)(11)(ii):  The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements:  Ribbon Blender:  On, or about, September 3, 2025, railings had not been provided on the right side, ascending, of the access stairs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 23, 2026
Penalty
Initial $2,838 · Current $1,987 Reduced
29 CFR  1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Production Area, Ribbon Blender:  On, or about, September 3, 2025, the Readco Ribbon Blender was not locked out while it was being cleaned.
Recent events (2)
  • — I (S) $1986.6
  • — Z (S) $2838

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 23, 2026
Penalty
Initial $2,838 · Current $1,987 Reduced
29 CFR  1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Production Area:  On, or about, September 3, 2025, an eyewash station was not provided where employees performed maintenance on forklift batteries that involved opening the batteries and adding water as needed.  The battery acid was a corrosive liquid with a pH of less than 1.
Recent events (2)
  • — I (S) $1986.6
  • — Z (S) $2838

1910.178 M02

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 23, 2026
Penalty
Initial $2,838 · Current $1,987 Reduced
29 CFR  1910.178(m)(2):  Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s):  On, or about, September 3, 2025, one ton sacks/bags of material were suspended from the forks of stand-up forklifts while the material was fed into Pulverizer machines.  Employees had to work under the suspended load to position the sacks/bags into the feed hopper and to operate machine controls:  A.	Pulverizer 1:  Allis Chalmers. B.	Pulverizer 2:  Crown.
Recent events (2)
  • — I (S) $1986.6
  • — Z (S) $2838

1910.219 C02 I

Serious Gravity 5 4 instances 7 exposed
Issued
Jan 23, 2026
Penalty
Initial $1,929 · Current $1,350 Reduced
29 CFR  1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  Packaging Area:  On, or about, September 3, 2025, horizontal drive shafts provided on the following packaging machines were not enclosed with a guard:  A.	Packaging Station 1. B.	Packaging Station 2. C.	Packaging Station 3. D.	Packaging Station 4.
Recent events (2)
  • — I (S) $1350.3
  • — Z (S) $1929

1910.303 G01 II

Serious Gravity 1 1 instance 7 exposed
Issued
Jan 23, 2026
Penalty
Initial $1,447 · Current $1,013 Reduced
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   Back of Production Area, Main Electrical Panels:  On, or about, September 3, 2025, pallets of material, pallets, bags and gaylords were stored in the working space in front of the panels.
Recent events (2)
  • — I (S) $1012.9
  • — Z (S) $1447

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):  The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition:  Pulverizer 1:  On, or about, September 3, 2025, a floor hole was located in the work space around the machine.  The hole was measured to be 5.75 inches in diameter and 10 inches deep and was large enough to create a tripping hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 A04

Other-than-serious 2 instances 7 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(4):  Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  A.	Shipping Receiving:  On, or about, September 3, 2025, the exit sign provided on the front wall was not lit. B.	Back Exit Door:  On, or about, September 3, 2025, the front panel was missing from the exit sign assembly that would show the work "EXIT".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 B05

Other-than-serious 3 instances 7 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(5):  Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  Production Area:  On, or about, September 3, 2025, three doors located along the wall adjacent to the office were not identified as non-exits:  A.	Brown door that led to office. B.	White door that led to unused attic space. C.	Blue door that led to an interior Tool Room.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A06

Other-than-serious 2 instances 7 exposed
Issued
Jan 23, 2026
Abate by
Mar 12, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.178(a)(6):  The employer did not ensure that all nameplates or markings were maintained in a legible condition:  A.	Pulverizer 2:  On, or about, September 3, 2025, the identification plate provided on the Crown stand-up forklift was worn and the information on the plate was difficult to read.  B.	Packaging Area:  On, or about, September 3, 2025, the identification plate provided on the Nissan sit-down forklift was worn and the information on the plate was difficult to read.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(4)(iii):  An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  Production Area:  On, or about, September 3, 2025, an employee who operated forklifts in the facility had not been provided with forklift training since October 26, 2021.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 7 exposed
Issued
Jan 23, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  Back Corner of Production Area:  On, or about, September 3, 2025, the raceway installed about the bank of electrical panels was not provided with a cover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Rose Mill Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348478470.