Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUSTOM CAST MARBLEWORKS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CUSTOM CAST MARBLEWORKS, INC. in 3154 EXON AVENUE, CINCINNATI, OH 45241 (NAICS 337110). OSHA activity number 348508706.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Cast Marbleworks, INC. — free Get an email when a new federal OSHA severe-injury report for Custom Cast Marbleworks, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3154 EXON AVENUE
City
CINCINNATI
State
OH
ZIP
45241
Mailing
3154 EXON AVE., CINCINNATI, OH 45241
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
30
Ownership type
A

4 citations on file for this inspection.

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2026
Abate by
Feb 18, 2026
Penalty
Initial $9,931 · Current $5,000 Reduced
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.  a)On or about September 17, 2025, the employer failed to ensure that the flexible cord set used for the mobile scissor lift table in the "set up area" was visually inspected for external defects before use. The cord was wrapped in multiple locations with electrical tape, which prevented the employee using the equipment from visually inspecting the outer jacket and insulation for damage. This failure exposed the employee to potential electrical shock and fire hazards from using a cord with unassessed damage.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9931

1910.305 A02 X

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2026
Abate by
Feb 18, 2026
Penalty
Initial $9,931 · Current $0 Reduced
29 CFR  1910.305(a)(2)(x):Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  a) On or about September 17, 2025, in the "set up area," the employer failed to protect a flexible electrical cord from accidental damage. The cord, which powered a mobile scissor lift table, was run across the floor where it was subjected to being run over by the lift and snagged on other objects. As a result, employees were exposed to electrical shock and fire hazards from damaged cords.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9931

1910.305 G01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2026
Abate by
Feb 18, 2026
Penalty
Initial $9,931 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:  1910.305(g)(1)(iv)(A) As a substitute for the fixed wiring of a structure;  a) On or about September 17, 2025, in the "set up area," the employer improperly used a flexible cord as a substitute for the fixed wiring of the structure. A flexible extension cord was secured by metal clips and tape over the plug while being used as a permanent, ongoing power supply for a mobile scissor lift that operated daily along a fixed path. As a result, employees were exposed to electrical shock and fire hazards from a cord being used in a manner for which it was not designed, leading to excessive wear and damage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9931

1910.22 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 26, 2026
Abate by
Feb 18, 2026
Penalty
Initial $11,916 · Current $0 Reduced
29 CFR  1910.22(a)(1):All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  a) On or about September 17, 2025, the employer failed to keep a passageway in the "set up area" in an orderly condition, in that a flexible electrical cord for a mobile scissor lift table (Manufacturer: MarMax Automation, Inc.) was laying  uncovered on the ground in the set up area aisle way where employee had to step over to enter and exit the area. As a result, employees were exposed to slip, trip and fall hazards.  The Custom Cast Marbleworks, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1453424, citation number 1, item number 1 and was affirmed as a final order on 01-21-2022, with respect to a workplace located at 3154 Exon Avenue CINCINNATI, OH 45241 UNITED STATES OF AMERICA.
Recent events (2)
  • — I (S) $0
  • — Z (R) $11916

View Custom Cast Marbleworks, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348508706.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.