AVON, NY —
OSHA Inspection: D. P. TOOL & MACHINE INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D. P. TOOL & MACHINE INC in 5638 TEC DRIVE, AVON, NY 14414 (NAICS 332721). OSHA activity number 348521857.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D. P. TOOL & MACHINE INC
- Site address
- 5638 TEC DRIVE
- City
- AVON
- State
- NY
- ZIP
- 14414
- Mailing
- 5638 TEC DRIVE, AVON, NY 14414
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 110
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 8, 2025
- Abate by
- Dec 31, 2025
- Penalty
- Initial $9,045 · Current $6,784 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 09/23/2025 throughout establishment; where employees perform servicing and/or maintenance activities such as, but not limited to: setting up presses, changing grinder wheels and replacing saw blades. The employer has not developed machine specific energy control procedures, nor has the employer trained to the authorized level or periodically reviewed employees performing covered operations where the employees were exposed to potentially hazardous energy sources and amputation hazards. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $6783.75
- — Z (S) $9045
1910.147 C04 I
- Issued
- Dec 8, 2025
- Abate by
- Dec 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 09/23/2025 throughout establishment; employees perform servicing and/or maintenance activities such as, but not limited to: setting up presses, changing grinder wheels and replacing saw blades without utilizing Lockout /Tagout (LOTO) procedures. Employees were exposed to amputation hazards. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Dec 8, 2025
- Abate by
- Dec 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) On or about 09/23/2025 throughout establishment; where employees perform servicing and/or maintenance activities such as, but not limited to: setting up presses or changing blades on saws, employees were not trained to recognize hazardous energy sources in the workplace and the means and methods (procedures) used to control those hazardous energy sources during servicing and/or maintenance of the machines and equipment in the workplace. Employees were exposed to amputation hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 E01 I
- Issued
- Dec 8, 2025
- Abate by
- Dec 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(e)(1)(i): The employer did not maintain a certification record of inspections which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the power press that was inspected. a) On or about 09/25/2025 in the Welding Department, employee(s) who operated the power presses were exposed to a caught between hazard when the employer did not establish an inspection program which included a certification and record of the inspection, the date performed, signature of who performed the inspection and an identifier of which press was inspected. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at D. P. Tool & Machine INC
View D. P. Tool & Machine INC's full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348521857.