HONEOYE FALLS, NY —
OSHA Inspection: K&H PRECISION PRODUCTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of K&H PRECISION PRODUCTS, INC. in 17 HIGH STREET, HONEOYE FALLS, NY 14472 (NAICS 331523). OSHA activity number 348567421.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- K&H PRECISION PRODUCTS, INC.
- Site address
- 17 HIGH STREET
- City
- HONEOYE FALLS
- State
- NY
- ZIP
- 14472
- Mailing
- 45 NORTON STREET, HONEOYE FALLS, NY 14472
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331523
- Employees
- 35
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.333 B02 I
- Issued
- Mar 2, 2026
- Penalty
- Initial $7,035 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(i):The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333. a) On or about 10/24/2025, throughout the establishment, employer did not maintain written procedures for safely de-energizing electrical circuits (480v/120v) for employees conducting electrical work, such as, but not limited to: troubleshooting electrical panels. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4000
- — Z (S) $7035
1910.333 B02 II B
- Issued
- Mar 2, 2026
- Penalty
- Initial $11,585 · Current $7,500 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(ii)(B):The circuits and equipment to be worked on were not disconnected from all electric energy sources: a) On or about 10/21/2025, in the Foundry, when an employee accessed the electrical control panel for #31 Melter without disconnecting both electrical energy sources, 120 and 480 Volts, the employee suffered an electrical burn when they came in contact with an energized part inside the panel. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $7500
- — Z (S) $11585
1910.333 C02
- Issued
- Mar 2, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2):Persons who were not qualified worked on electrical circuit parts or equipment that had not been de-energized under the procedures of paragraph (b) of this section. Such persons were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment. a) On or about 10/21/2025, in the Foundry, a maintenance employee who was not a qualified electrical employee accessed an energized electrical panel without having training in the skills or techniques required to recognize and control electrical hazards of an electrical panel with multiple energy sources (#31 Melter). The employee suffered an electrical burn when they came in contact with an energized part inside the panel while troubleshooting the panel. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Mar 2, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $4,965 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about 10/24/2025, in the Foundry, where employees were exposed to electrical shock hazards when there were unused openings (missing knockouts) in the electrical panel for the #31 Melter. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $4965
1910.147 C05 II D
- Issued
- Mar 2, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $930 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s) a) On or about 10/24/2025, in the Foundry, the tag on the lock applied as energy isolating devices on the breaker for #31 Melter did not identify the name of the employee who applied the lockout/tagout device. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $500
- — Z (O) $930
1910.147 C04 II B
- Issued
- Mar 2, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $930 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) On or about 10/24/2025, Foundry, where employees operate machines such as, but not limited to #31 Melter, #32 Melter, #33 Melter, the energy control procedures did not identify the magnitude of the energy sources or the specific energy isolating means for controlling each energy source. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (O) $500
- — Z (O) $930
More inspections at K&H Precision Products, INC.
View K&H Precision Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331523)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348567421.