Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CABINETWORKS GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CABINETWORKS GROUP in 11823 LENAPE DRIVE, MOUNT UNION, PA 17066 (NAICS 337110). OSHA activity number 348597519.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cabinetworks Group — free Get an email when a new federal OSHA severe-injury report for Cabinetworks Group is published. One employer, no account, unsubscribe in one click.
Establishment
CABINETWORKS GROUP
Site address
11823 LENAPE DRIVE
City
MOUNT UNION
State
PA
ZIP
17066
Mailing
11823 LENAPE DRIVE, MOUNT UNION, PA 17066
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337110
Employees
156
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 50 exposed
Issued
Jan 21, 2026
Abate by
Feb 17, 2026
Penalty
Initial $16,550 · Current $16,550

Hazardous substances E200

OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from deflagration hazards created by the generation of dust clouds.  a. The Mill - On or about November 18, 2025, employees performing daily housekeeping would conduct a blowdown of the equipment with compressed air, the practice of blowdown in areas with combustible dust from the cabinet milling process exposed employees to deflagration and combustible dust explosion hazards.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (S) $16550
  • — Z (S) $16550

1910.307 C

Serious Gravity 10 1 instance 50 exposed
Issued
Jan 21, 2026
Abate by
Feb 17, 2026
Penalty
Initial $0 · Current $0

Hazardous substances E200

29 CFR  1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:   a. The Mill - On or about November 18, 2025, the electrical boxes, controllers, conduit, and electrically powered milling equipment to include saws and robots were not rated for class II dust environment, employees were exposed to deflagration and dust explosion hazards.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 10 exposed
Issued
Jan 21, 2026
Penalty
Initial $7,093 · Current $7,093
29 CFR  1910.303(b)(2): Listed or labeled: electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. Mill - On or about November 18, 2025, the employer had plugged a relocatable power tap into an extension cord (daisy chaining), exposing employees to an electrical hazard.  b. Conference Room - On or about November 18, 2025, the employer had plugged a relocatable power tap into an extension cord (daisy chaining), exposing employees to an electrical hazard.  Corrected During Inspection
Recent events (2)
  • — C (S) $7093
  • — Z (S) $7093

View Cabinetworks Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348597519.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.