EARTH CITY, MO —
OSHA Inspection: BELTSERVICE CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BELTSERVICE CORPORATION in 4143 RIDER TRAIL NORTH, EARTH CITY, MO 63045 (NAICS 326299). OSHA activity number 348606351.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELTSERVICE CORPORATION
- Site address
- 4143 RIDER TRAIL NORTH
- City
- EARTH CITY
- State
- MO
- ZIP
- 63045
- Mailing
- 4143 RIDER TRAIL NORTH, EARTH CITY, MO 63045
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 200
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A03 III
- Issued
- Jan 6, 2026
- Abate by
- Jan 29, 2026
- Penalty
- Initial $16,550 · Current $9,930 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(iii): Special hand tools for placing and removing materials were not provided to permit easy handling of materials without the operator placing a hand in the danger zone. On or about October 10, 2025, the employer did not ensure that special hand tools were provided or used to prevent employees from placing their hands in the danger zone while adjusting a conveyor belt through a slitter machine (MO 203-4-99/72-20K/SN 2120) located at 4143 Rider Trail North, in Earth City MO. An employee sustained a crushing injury to his right middle finger when it was caught between a roller bar and table/conveyor belt while guiding the conveyor belt through the slitter machine.
Recent events (2)
- — I (S) $9930
- — Z (S) $16550
1910.303 B02
- Issued
- Jan 6, 2026
- Abate by
- Jan 29, 2026
- Penalty
- Initial $11,348 · Current $6,809 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about November 19, 2025, at the facility located at 4143 Rider Trail North, Earth City, MO, the employer did not ensure that power strips in the slitter area were used in accordance with the manufacturer's listing and labeling. The computer workstations had multiple power strips plugged into one another and had high-power load items, such as a refrigerator and a microwave, connected to them.
Recent events (2)
- — I (S) $6808.8
- — Z (S) $11348
1910.305 G01 IV A
- Issued
- Jan 6, 2026
- Abate by
- Jan 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about November 19, 2025, at the facility located at 4143 Rider Trail North, Earth City, MO, the employer used a flexible cord as a substitute for fixed wiring to power computer equipment, a printer, and multiple power strips daisy-chained together, thereby creating an electrical hazard for employees using the equipment and working in the area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jan 6, 2026
- Abate by
- Jan 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 11/19/2025, in the facility located at 4143 Rider Trail North, in Earth City MO, the employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and the requirements of this standard were followed. Without the proper knowledge and safe application of energy control, employees are exposed to caught-in and entanglement hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Beltservice Corporation
View Beltservice Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348606351.