WINDSOR LOCKS, CT —
OSHA Inspection: EAST WINDSOR DONUTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAST WINDSOR DONUTS, INC. in 94 MAIN STREET, WINDSOR LOCKS, CT 06096 (NAICS 722513). OSHA activity number 348613290.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST WINDSOR DONUTS, INC.
- Site address
- 94 MAIN STREET
- City
- WINDSOR LOCKS
- State
- CT
- ZIP
- 06096
- Mailing
- P.O. BOX 1028, EAST WINDSOR, CT 06088
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722513
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.176 B
- Issued
- Jan 28, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $4,502 · Current $3,151 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: Back Room: On, or about, November 25, 2025, a screw driver was used to prevent a storage rack from tipping forward. The storage rack was used to store drink mixes and flavorings.
Recent events (2)
- — I (S) $3151.4
- — Z (S) $4502
1910.304 B04 II B
- Issued
- Jan 28, 2026
- Penalty
- Initial $2,870 · Current $2,009 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4: Counter Area: On, or about, November 25, 2025, a 15 ampere relocatable power tap was used to energize a refrigerator and a hot chocolate machine with a combined load of 19 amperes. The maximum load allowed the relocatable power tap was 12 amperes.
Recent events (2)
- — I (S) $2009
- — Z (S) $2870
More inspections at East Windsor Donuts, INC.
View East Windsor Donuts, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 722513)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348613290.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.