1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: MENK USA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MENK USA, LLC in 2207 ENTERPRISE DRIVE, STERLING, IL 61081 (NAICS 335311). OSHA activity number 348624446.

Watch Menk USA, LLC — free Get an email when a new federal OSHA severe-injury report for Menk USA, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MENK USA, LLC
Site address
2207 ENTERPRISE DRIVE
City
STERLING
State
IL
ZIP
61081
Mailing
2207 ENTERPRISE DRIVE, STERLING, IL 61081
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335311
Employees
93
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6621.00 · Current $4500.00 Reduced
29 CFR  1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On or about November 18, 2025,  the employer did not conduct a periodic inspection of the energy?control procedures for the element?line plasma assembly. Employees were performing maintenance on the plasma section, including replacing air cylinders, shock absorbers, and related components, without any documented annual review of the lockout/tagout (LOTO) procedures.  Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $4500
  • — Z (S) $6621

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9268.00 · Current $0.00 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  On or about November 18, 2025, the employer did not ensure that the required steps for the application of energy control were followed prior to servicing the element?line plasma assembly.   An employee replaced Spring #1 and Spring #2 within the plasma section assembly without shutting down, isolating, or locking out the machine.  Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $9268

1910.147 F01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $6500.00
29 CFR  1910.147(f)(1):Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the sequence of actions in this section shall be followed.  On or about November 18, 2025, the employer did not ensure that employees followed the required safe?testing sequence for energized activation of pneumatic air cylinders within the plasma assembly of the element line.  An employee was positioned at the point of operation while testing the air cylinders and received a fingertip amputation.  Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $6500
  • — Z (S) $0

View MENK USA, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348624446.