Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUANEX HOMESHIELD, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUANEX HOMESHIELD, LLC in 311 W COLEMAN STREET, RICE LAKE, WI 54868 (NAICS 337212). OSHA activity number 348677378.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quanex Homeshield, LLC — free Get an email when a new federal OSHA severe-injury report for Quanex Homeshield, LLC is published. One employer, no account, unsubscribe in one click.
Site address
311 W COLEMAN STREET
City
RICE LAKE
State
WI
ZIP
54868
Mailing
311 W COLEMAN STREET, RICE LAKE, WI 54868
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337212
Employees
359
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Other-than-serious Gravity 10 1 instance 8 exposed
Issued
Jun 8, 2026
Abate by
Jun 30, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Fireplace area, finishing presses; On or about January 8, 2026 and dates prior, the written energy isolation procedures for controlling electrical, pneumatic, and stored (gravity) energy were not utilized while employees performed servicing activities of setup/changeover operations on double-sided finishing presses (FIN 004 and FIN 008).  Rather, operators used an unwritten procedure that relied on turning a rotary switch to the off position, so the material/shuttle table they were setting up would not move beneath the ram while the electrical, pneumatic, and stored energy for the ram and shuttle table remained energized.
Recent events (2)
  • — I (O) $16550
  • — Z (S) $16550

1910.147 C04 II B

Other-than-serious Gravity 10 1 instance 8 exposed
Issued
Jun 8, 2026
Abate by
Jun 30, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  (a) Fireplace area, finishing presses; On or about May 8, 2024, and dates prior, written energy isolation (LOTO) procedures for double-sided finishing presses (FIN 004 and FIN 008) did not identify how stored energy (gravity) from the ram (press head) would be isolated and/or secured to prevent movement during servicing and/or maintenance activities.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C07 I A

Other-than-serious Gravity 10 1 instance 7 exposed
Issued
Jun 8, 2026
Abate by
Aug 31, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:     (a) Fireplace area, finishing presses; On or about January 8, 2026 and dates prior, authorized level lockout training was not provided to each employee before they performed servicing activities of setting up double-sided finishing presses (FIN 004 and 008).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 D03

Other-than-serious Gravity 10 1 instance 8 exposed
Issued
Jun 8, 2026
Abate by
Jun 30, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:  (a) Fireplace area, finishing presses; On or about January 8, 2026 and dates prior, energy isolating devices were not used to control electrical, pneumatic, and stored (gravity) energy sources before setup/changeover operations were conducted on double sided finishing presses (FIN 004 and 008).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 D04 I

Other-than-serious Gravity 10 1 instance 8 exposed
Issued
Jun 8, 2026
Abate by
Jun 30, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Fireplace area, finishing presses; On or about January 8, 2026 and dates prior, lockout/tagout devices were not affixed to each energy isolating device for electrical, pneumatic, and stored (gravity) energy sources before setup/changeover operations were conducted on double-sided finishing presses (FIN 004 and 008).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0