Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PAUL'S FRAMING PRO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PAUL'S FRAMING PRO, INC. in 211 PARK AVE, GLENCOE, IL 60022 (NAICS 238130). OSHA activity number 348677527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paul'S Framing PRO, INC. — free Get an email when a new federal OSHA severe-injury report for Paul'S Framing PRO, INC. is published. One employer, no account, unsubscribe in one click.
Site address
211 PARK AVE
City
GLENCOE
State
IL
ZIP
60022
Mailing
684 MEADOWSEDGE LN., AURORA, IL 60506
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2026
Penalty
Initial $4,256 · Current $2,200 Reduced
29 CFR  1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) On January 6, 2026, at the above addressed jobsite, employees were exposed to struck-by hazards from moving and swinging loads that were being transported by a crane and received by the exposed employees.  The employees were not wearing hard hats.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4256

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 24, 2026
Penalty
Initial $4,256 · Current $2,200 Reduced
29 CFR  1926.102(a)(1): The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a) On January 6, 2026, at the above addressed jobsite, employees were exposed to eye injury while operating pneumatic nailers and saws without eye protection.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4256

1926.451 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2026
Abate by
Mar 20, 2026
Penalty
Initial $2,837 · Current $1,500 Reduced
29 CFR  1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide:  a) On January 6, 2026, at the above addressed jobsite, the wood carpenters scaffold that was provided to employees performing carpentry work approximately 7 feet above the concrete floor was provided with walking platforms that were approximately 6 inches wide, exposing the employee to falls.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2837

1926.451 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 24, 2026
Abate by
Mar 20, 2026
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:  a) On January 6, 2026, at the above addressed jobsite, the wood carpenters scaffold that was provided to employees performing carpentry work approximately 7 feet above the concrete floor, was not erected with level, sound and rigid footing.  The footings on numerous supports were not secure or provided with base plates, thereby exposing the employee to falls.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 3 instances 3 exposed
Issued
Feb 24, 2026
Penalty
Initial $4,965 · Current $2,900 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   a) On January 6, 2026, at the above addressed jobsite, employees engaged in framing activities were exposed to falls of approximately 10 feet 4 inches without the use of fall protection.  Employees were exposed to interior falls from the top of trusses to the interior floor.    b) On January 6, 2026, at the above addressed jobsite, employees engaged in framing activities were exposed to falls of approximately 11 feet 4 inches without the use of fall protection.  Employees were exposed to exterior falls from the top of trusses to the exterior ground on the north, west, and southwest sides of the area of the house being constructed.  Employees were exposed to exterior falls from the top of a trusses to the ground.    c) On January 6, 2026, at the above addressed jobsite, employees engaged in framing activities were exposed to falls of up to approximately 18 feet 10 inches without the use of fall protection.  Employees were exposed to exterior falls from the top of trusses to the exterior ground on the south side of the area of the house being constructed.  Employees were exposed to exterior falls from the top of a trusses to the ground.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 24, 2026
Penalty
Initial $4,256 · Current $2,200 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On January 6, 2026, at the above addressed jobsite, the portable Werner Fiberglass A-frame ladder used by an employee to access and egress the middle of the roof where trusses were being set, measuring approximately 10 feet 4 inches from the ground, did not extend to have the side rails extend at least three (3) feet above the upper landing.  b) On January 6, 2026, at the above addressed jobsite, the portable Gorilla Ladder used by an employee to access and egress the carpenters scaffold on the south wall of the home, measuring approximately 6 feet 6 inches from the ground, did not extend to have the side rails extend at least three (3) feet above the upper landing.   c) On January 6, 2026, at the above addressed jobsite, the portable Werner Fiberglass A-frame ladder used by an employee to access and egress the carpenters scaffold on the north wall of the home, measuring approximately 6 feet 11 inches from the ground, did not extend to have the side rails extend at least three (3) feet above the upper landing.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4256