PORTSMOUTH, RI —
OSHA Inspection: SHM NEB, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHM NEB, LLC in 1 LAGOON ROAD, PORTSMOUTH, RI 02871 (NAICS 336612). OSHA activity number 348701947.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SHM NEB, LLC
- Site address
- 1 LAGOON ROAD
- City
- PORTSMOUTH
- State
- RI
- ZIP
- 02871
- Mailing
- 1 LAGOON ROAD, PORTSMOUTH, RI 02871
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 112
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 27, 2026
- Penalty
- Initial $12,059 · Current $6,030 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Building #9 Metal Fabrication Shop: On or about January 22, 2026, employees were exposed to struck-by and struck-against hazards while operating a Precision Matthews Lathe Model PM-1440HVT-2 without spindle guarding.
Recent events (2)
- — I (S) $6029.5
- — Z (S) $12059
1910.134 G01 I A
- Issued
- Mar 27, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $1,355 · Current $678 Reduced
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function. a) Building #4: On or about January 22, 2026, the employer did not ensure that employees wearing tight-fitting respirators such as 3M FF80 & HF800 were clean shaven to achieve a proper seal.
Recent events (2)
- — I (O) $677.5
- — Z (O) $1355
1910.305 G01 IV A
- Issued
- Mar 27, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $1,355 · Current $678 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) Building #7 SawStop Table Saw: On or about January 22, 2026, employees were exposed to electrical hazards while using a black SJ cord without GFCI protection to provide power to the SawStop Table Saw. b) Building #7 Jess Em Tool Company Router: On or about January 22, 2026, employees were exposed to electrical hazards while using an extension cord without GFCI protection to provide power to the Jess Em Tool Company Router. c) Building #10 Composite Shop: On or about January 22, 2026, employees were exposed to electrical hazards while using a black SJ cord without GFCI protection to provide power to the LED lighting above.
Recent events (2)
- — I (O) $677.5
- — Z (O) $1355
1910.305 G01 IV B
- Issued
- Mar 27, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors. a) Building #10 Composite Shop: On or about January 22, 2026, employees were exposed to electrical hazards while using a black SJ cord running through a wall to provide power to the LED lighting above.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV D
- Issued
- Mar 27, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces. a) Building #7 SawStop Table Saw: On or about January 22, 2026, employees were exposed to electrical hazards due to a black SJ cord that was attached to the building providing power to the SawStop Table Saw.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SHM NEB, LLC
View SHM NEB, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348701947.