Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALABAMA GOODWILL INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ALABAMA GOODWILL INDUSTRIES, INC. in 2350 GREEN SPRINGS HIGHWAY, BIRMINGHAM, AL 35205 (NAICS 452210). OSHA activity number 348709429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alabama Goodwill Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Alabama Goodwill Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2350 GREEN SPRINGS HIGHWAY
City
BIRMINGHAM
State
AL
ZIP
35205
Mailing
2350 GREEN SPRINGS HIGHWAY, BIRMINGHAM, AL 35205
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
452210
Employees
90
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 12 exposed
Issued
May 1, 2026
Abate by
Jun 29, 2026
Penalty
Initial $14,187 · Current $8,512 Reduced
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  (a) On or about January 26, 2026, Warehouse Area; an exit door was obstructed by a large floor scale and electrical cords placed in front of the door.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $8512.2
  • — Z (S) $14187

1910.157 C01

Serious Gravity 5 2 instances 12 exposed
Issued
May 1, 2026
Abate by
Jun 29, 2026
Penalty
Initial $9,457 · Current $5,674 Reduced
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:       (a) On or about January 26, 2026, Processing Area: a fire extinguisher was obstructed by stored materials (bins, boxes, carts, and miscellaneous items), preventing immediate access in the event of a fire emergency.   (b) On or about January 26, 2026, Warehouse Area: two fire extinguishers were obstructed by stored materials (bins, boxes, carts, and miscellaneous items), preventing immediate access in the event of a fire emergency.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $5674.2
  • — Z (S) $9457

1910.176 A

Serious Gravity 5 1 instance 12 exposed
Issued
May 1, 2026
Abate by
Jun 29, 2026
Penalty
Initial $14,187 · Current $8,512 Reduced
29 CFR  1910.176(a): Aisle(s) and passageway(s) were not kept clear and in good repair with no obstruction across or in aisles that could create a hazard.  (a) On or about January 26,2026, Warehouse; aisle(s) were obstructed with boxes and bins of materials.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $8512.2
  • — Z (S) $14187

1910.303 G01 II

Serious Gravity 5 2 instances 12 exposed
Issued
May 1, 2026
Abate by
Jun 29, 2026
Penalty
Initial $14,187 · Current $8,512 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   (a) On or about January 26, 2026, West Area of  Warehouse; merchandise was stored outside the fenced area where two electrical panels were located.  (b)  On or about January 26, 2026, East Area of Warehouse; clothing and materials were stored directly in front of an electrical panel.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $8512.2
  • — Z (S) $14187

1910.37 B02

Other-than-serious 1 instance 12 exposed
Issued
May 1, 2026
Abate by
Jun 29, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   (a) On or about January 26,2026, Warehouse; a door used as an exit by employees for egress to the exterior (side parking lot) was not marked as an "Exit" door.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 12 exposed
Issued
May 1, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     (a) On or about January 26, 2026, Warehouse; a relocatable power tap (RPT) was used to supply power to equipment such as, but not limited to, a large floor scale and a fan.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Alabama Goodwill Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348709429.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.