Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRIGHTPET NUTRITION GROUP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRIGHTPET NUTRITION GROUP, LLC in 38251 INDUSTRIAL PARK ROAD, LISBON, OH 44432 (NAICS 311111). OSHA activity number 348727231.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brightpet Nutrition Group, LLC — free Get an email when a new federal OSHA severe-injury report for Brightpet Nutrition Group, LLC is published. One employer, no account, unsubscribe in one click.
Site address
38251 INDUSTRIAL PARK ROAD
City
LISBON
State
OH
ZIP
44432
Mailing
38251 INDUSTRIAL PARK ROAD, LISBON, OH 44432
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311111
Employees
76
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 18, 2026
Penalty
Initial $11,585 · Current $8,110 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:(a):  On or about January 29, 2026, BrightPet Nutrition Group, LLC dba Ohio Pet Foods Inc failed to document and ensure employees utilize procedures for the control of the hazardous electrical energy source of the Cyclone Airlock Machine of the Geenlen Counterflow Cooler when engaged in service and maintenance activities such as cleaning and clearing of jams inside the machine.
Recent events (2)
  • — I (S) $8110
  • — Z (S) $11585

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 18, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:    On or about January 29, 2026, BrightPet Nutrition Group, LLC dba Ohio Pet Foods Inc did not ensure employees performing cleaning and servicing activities by unjamming kibble and dust out of the Cyclone Airlock of the Geenlen Counterflow Cooler followed the established energy control procedures by; turning off or shutting down the Cyclone Airlock [per 1910.147(d)(2)], isolating the Cyclone Airlock from the electrical energy sources [(d)(3)], affixing lockout device(s) to the energy isolation devices [(d)(4)(i)], and verifying de-energization and isolation had been accomplished [(d)(6)], prior to the removing of a panel and checking for jams of kibble and dust from the Cyclone Airlock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Brightpet Nutrition Group, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348727231.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.