ROME, NY ·
OSHA Inspection: NORTEK POWDER COATING LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NORTEK POWDER COATING LLC in 5900 SUCCESS DRIVE, ROME, NY 13440 (NAICS 325510). OSHA activity number 348751033.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTEK POWDER COATING LLC
- Site address
- 5900 SUCCESS DRIVE
- City
- ROME
- State
- NY
- ZIP
- 13440
- Mailing
- 5900 SUCCESS DRIVE, ROME, NY 13440
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 25
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 18, 2026
- Penalty
- Initial $3,405 · Current $2,043 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards: a.) Grinder 1 Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; The employer did not complete a periodic inspection of the hoist used to lift bins of chips from the extruders onto the grinding platform. 1/2 ton wall mount Gorbel straight beam rail with an underhung 1 ton Milwaukee hoist (model: 9566, SN JMA0965XB). b.) Grinder 2 Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; The employer did not complete a periodic inspection of the hoist used to lift bins of chips from the extruders onto the grinding platform. 1/2 ton wall mount Gorbel straight beam rail with an underhung 1 ton Coffing hoist (model: JLC2016, SN JMA5058Q8).
Recent events (2)
- · I (S) $2043
- · Z (S) $3405
1910.28 B01 I
- Issued
- Jun 18, 2026
- Abate by
- Jul 23, 2026
- Penalty
- Initial $3,405 · Current $2,043 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a.) Grinder 1, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees were exposed to a fall hazard of approximately 6 feet 11 inches when walking by the loading area on the platform at Grinder 1, no guard rails were present. b.) Grinder 2, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees were exposed to a fall hazard of approximately 6 feet 11 inches when walking by the loading area on the platform at Grinder 2, no guard rails were present. c.) Large Mixers, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees were exposed to a fall hazard of approximately 5 feet 6 inches when when placing raw materials into the large mixers. No guardrails were present where pallets of material are positioned on the platform. d.) Smaller Mixers, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees were exposed to a fall hazard of approximately 5 feet when placing raw materials into the large mixers. No guardrails were present where pallets of material are positioned on the platform. Abatement certification is required.
Recent events (2)
- · I (S) $2043
- · Z (S) $3405
1910.29 B02 I
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(2)(i): The employer did not ensure that guardrails met the requirement that midrails that are installed at a height midway between the top edge of the guardrail system and the walking-working surface. a.) Grinder 5, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees were exposed to a fall hazard of approximately 7 feet, the platform above the grinder did not have a midrail at the forklift loading area. Abatement certification is required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 D04 V
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $4,256 · Current $2,554 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(v): In every inside storage room there was not one clear aisle maintained at least 3 feet wide. a.) Flammable Liquid Storage Room, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; An aisle at least 3 feet wide was not maintained in the flammable liquid storage room. A 55?gallon drum of methyl ethyl ketone was positioned directly inside the doorway, restricting access and egress. Abatement certification is required.
Recent events (2)
- · I (S) $2553.6
- · Z (S) $4256
1910.106 E02 II
- Issued
- Jun 18, 2026
- Abate by
- Jul 23, 2026
- Penalty
- Initial $0 · Current $0
0430
General-duty citation text
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers: a.) Flammable Liquid Storage Room, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees accumulated leftover methyl ethyl ketone (Category 2 flammable liquid) in an open?top drum; the lid was kept off the drum. Abatement certification is required
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 E06 II
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $0 · Current $0
0430
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), was dispensed into containers unless the nozzle and container are electrically interconnected. a.) Flammable Liquid Storage Room, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Methyl ethyl ketone (Category 2 flammable liquid) was dispensed from a 55?gallon drum positioned horizontally on a rack, with its contents poured into a metal bucket. The drum and bucket were not electrically interconnected (bonded/grounded) during dispensing. Abatement certification is required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C02 II
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $3,405 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a.) Mixing, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; The employer allowed employees to voluntarily wear respiratory protection and did not ensure the user was medically able to use that respirator (half face elastomeric, 3M, Model: 5200). Abatement certification is required.
Recent events (2)
- · I (S) $0
- · Z (S) $3405
1910.147 C04 II B
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $3,405 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a.) Grinders, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees are required to disassemble and clean the grinders between products and the employer did not establish a procedure that clearly outlined the steps to be followed to control hazardous energy. Abatement certification is required.
Recent events (2)
- · I (S) $0
- · Z (S) $3405
1910.147 C04 I
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $8,513 · Current $5,108 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a.) Grinders, Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; Employees are required to disassemble and clean the grinders and the employer did not have employees utilize lockout tagout. Nortek Powder Coating LLC was previously cited for a violation of the Occupational Safety and Health Standard, its equivalent, or essentially similar standard 29 CFR 1910.147(c)(4)(i) which was contained in OSHA inspection number 1586572 , Citation number 1, Item number 3, Issued on 9/28/2022, and affirmed as a final order on 6/24/2024 with respect to a workplace located at 5900 Success Drive, Rome, NY, 13440.
Recent events (2)
- · I (R) $5107.8
- · Z (R) $8513
1904.32 A04
- Issued
- Jun 18, 2026
- Penalty
- Initial $851 · Current $0 Reduced
General-duty citation text
29 CFR 1904.32(a)(4): The employer did not post an OSHA Form 300A or equivalent by February 1. a.) Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; The employer did not create or post an annual summary for injuries and illnesses.
Recent events (2)
- · I (O) $0
- · Z (O) $851
1910.178 L04 III
- Issued
- Jun 18, 2026
- Abate by
- Jul 16, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a.) Nortek Powder Coating LLC, 5900 Success Drive, Rome, NY, 13440, on or about 2/17/2026; The employer did not provide for an evaluation of each powered industrial truck operator at least once every three years. Abatement certification is required.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Nortek Powder Coating LLC
View Nortek Powder Coating LLC's full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348751033.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.