DENVER, CO —
OSHA Inspection: GRAYBAR ELECTRIC COMPANY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GRAYBAR ELECTRIC COMPANY INC. in 480 EAST 55TH AVENUE, DENVER, CO 80216 (NAICS 423610). OSHA activity number 348788092.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GRAYBAR ELECTRIC COMPANY INC.
- Site address
- 480 EAST 55TH AVENUE
- City
- DENVER
- State
- CO
- ZIP
- 80216
- Mailing
- 480 EAST 55TH AVENUE, DENVER, CO 80216
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423610
- Employees
- 144
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.151 C
- Issued
- May 19, 2026
- Abate by
- Jun 15, 2026
- Penalty
- Initial $8,038 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about March 5, 2025, the employer did not provide suitable facilities for quick drenching or flushing of the eyes and body where employees were exposed to Sulfuric acid (battery acid) during change out of forklift batteries. This potentially exposed employees to chemical skin burns.
Recent events (2)
- — I (S) $0
- — Z (S) $8038
1910.176 B
- Issued
- May 19, 2026
- Abate by
- Jun 15, 2026
- Penalty
- Initial $12,059 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: On or about March 5, 2026, employees were exposed to struck?by hazards from falling objects where small items (e.g., boxes/loose components) were stored loose and unsecured on pallets on the top of a multi?tier storage racks. The materials were not stacked, blocked, interlocked, and limited in height to ensure stability and to prevent sliding or collapse.
Recent events (2)
- — I (S) $0
- — Z (S) $12059
1910.303 G01 I B
- Issued
- May 19, 2026
- Abate by
- Jun 15, 2026
- Penalty
- Initial $10,050 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater : On or about March 5, 2028, the employer did not maintain the required clear working space in front of an electrical panelboard from the following: a) East end at the battery charging station a wall?mounted portable eyewash station was installed approximately 11 inches from the panel b) West end at the shipping doors a forklift was parked in the assess point of the electrical panel board
Recent events (2)
- — I (S) $0
- — Z (S) $10050
More inspections at Graybar Electric Company INC.
View Graybar Electric Company INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423610)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348788092.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.