RIDGEFIELD, CT —
OSHA Inspection: JAY BUILDERS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JAY BUILDERS, LLC in 16 KEELER PLACE, RIDGEFIELD, CT 06877 (NAICS 238160). OSHA activity number 348822016.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JAY BUILDERS, LLC
- Site address
- 16 KEELER PLACE
- City
- RIDGEFIELD
- State
- CT
- ZIP
- 06877
- Mailing
- 60 MORNINGSIDE AVENUE, WATERBURY, CT 06708
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.502 D09
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $5,958 · Current $5,958
General-duty citation text
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN): 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the employer did not ensure that the shock absorbing lanyard had a minimum breaking strength of 5,000 pounds where the personal fall arrest system lanyard with a knot was used by a day laborer performing roofing activities at 18 feet and 5 inches above the ground.
Recent events (1)
- — Z (S) $5958
1926.502 D16 III
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $5,958 · Current $5,958
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the personal fall arrest system used by a day laborer was not rigged in a way to prevent the worker from falling 18 feet and 5 inches and making contact with the lower level.
Recent events (1)
- — Z (S) $5958
1926.502 D21
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $5,958 · Current $5,958
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the personal fall arrest system used by a day laborer was not inspected for defects and removed from service, such as the knot in the lanyard fabric the day laborer used while working on a roof more than 18 feet above a lower level.
Recent events (1)
- — Z (S) $5958
1926.1053 B05 I
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $5,958 · Current $5,958
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the employer permitted the day laborer to use the extension ladder placed at an unsafe angle where the foot of the ladder was more than one-third the working length of the ladder away from the base of the structure.
Recent events (1)
- — Z (S) $5958
1926.503 A01
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $11,916 · Current $11,916
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the employer did not provide fall hazard training to the day laborer who was required to work from a steep pitched residential roof while installing underlayment and exposed to fall hazards of 18 feet and 5 inches. Jay Builders, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1), which was contained in OSHA inspection number 1677484, citation number 1, item number 1b and was affirmed as a final order on August 23, 2023, with respect to a workplace located at 27 Dunhurst Place in Darien Connecticut.
Recent events (1)
- — Z (R) $11916
1926.1060 A
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $11,916 · Current $11,916
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the employer did not provide training in procedures to minimize hazards related to ladder use for the day laborer using an aluminum extension ladder while performing residential roofing activities. Jay Builders, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1060(a), which was contained in OSHA inspection number 1677484, citation number 1, item number 3b and was affirmed as a final order on August 23, 2023, with respect to a workplace located at 27 Dunhurst Place in Darien Connecticut.
Recent events (1)
- — Z (R) $11916
1926.1053 B09
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the employer did not ensure the area around the bottom of the aluminum extension ladder at the front of the worksite was kept clear to prevent a tripping hazard.
Recent events (1)
- — Z (O) $0
1926.1053 B16
- Issued
- Apr 20, 2026
- Abate by
- Jun 5, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: 16 Keeler Place, Ridgefield CT: On or about March 19, 2026, the employer permitted the use of an extension ladder with a defective component including a bent rung, by a day laborer performing roofing activities.
Recent events (1)
- — Z (O) $0
More inspections at JAY Builders, LLC
View JAY Builders, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348822016.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.