Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NOVELIS ALR ROLLED PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NOVELIS ALR ROLLED PRODUCTS, INC. in 1 REYNOLDS ROAD, ASHVILLE, OH 43103 (NAICS 332812). OSHA activity number 348822719.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Novelis ALR Rolled Products, INC. — free Get an email when a new federal OSHA severe-injury report for Novelis ALR Rolled Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 REYNOLDS ROAD
City
ASHVILLE
State
OH
ZIP
43103
Mailing
1 REYNOLDS ROAD, ASHVILLE, OH 43103
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
186
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 3, 2026
Penalty
Initial $16,550 · Current $12,500 Reduced
29 CFR  1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (A) A specific statement of the intended use of the procedure; (B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and (D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  a) On or about March 9, 2026, located in the Production Department, employees changed rubber rolls on the Narrow Coat Line without having procedures for employees to utilize that provided the necessary specific information as required for the control of hazardous energy. The procedure did not include specific steps for isolating and securing the pneumatic energy [B], placement of lockout devices onto the pneumatic energy [C], and verifying that the pneumatic energy was isolated [D].
Recent events (2)
  • — I (S) $12500
  • — Z (S) $16550

1910.147 C06 I

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 3, 2026
Penalty
Initial $16,550 · Current $0 Reduced
29 CFR  1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about March 9, 2026, located in the Production Department, the employer failed to conduct an adequate periodic inspection of the energy control procedure for the Narrow Coat Line-Wet Section in that energy sources were not identified or controlled, thereby exposing employees to caught-in hazards during squeegee roll changes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16550

1910.147 D

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 3, 2026
Penalty
Initial $16,550 · Current $12,500 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a) On or about March 9, 2026, located in the Production Department, employees were exposed to machine hazards associated with Narrow Coat Line-Wet Section while performing servicing and maintenance activities, including changing squeegee rolls. The employer failed to implement energy control application steps as the pneumatic energy was not isolated and controlled prior to performing the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving air isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $12500
  • — Z (S) $16550

View Novelis ALR Rolled Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348822719.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.