PIQUA, OH —
OSHA Inspection: SCOTT STEEL LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SCOTT STEEL LLC in 125 CLARK AVE., PIQUA, OH 45356 (NAICS 423510). OSHA activity number 348848003.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCOTT STEEL LLC
- Site address
- 125 CLARK AVE.
- City
- PIQUA
- State
- OH
- ZIP
- 45356
- Mailing
- 125 CLARK AVE SUITE A, PIQUA, OH 45356
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 5, 2026
- Abate by
- Jul 10, 2026
- Penalty
- Initial $9,268 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a) On or about March 26, 2026, the employer did not ensure that the automatic coil pusher on the Thor/Fury coil turnstile was guarded to prevent employee exposure to the point of operation while transferring coils onto the Braner down layer table. Employees were exposed to a caught between hazard created by the unguarded pusher advancing toward the coil b) On or about March 26, 2026, the employer did not ensure that the retractable horn on the Braner Coil Down Layer Table was guarded to prevent employee exposure to pinch points while employees were transferring coils from the Thor/Fury coil turnstile onto the table. Employees were exposed to a pinch point hazard created by the retractable horn moving toward the coil turnstile arms. c) On or about March 26, 2026, the employer did not ensure that the lifting and descending Braner Coil Down Layer Table was guarded to prevent employee exposure to pinch points while employees were transferring coils from a coil turnstile onto the table. Employees were exposed to a pinch point hazard created by the table moving toward its supporting structure.
Recent events (2)
- — I (S) $6000
- — Z (S) $9268
1910.147 C04 II
- Issued
- Jun 5, 2026
- Abate by
- Jul 24, 2026
- Penalty
- Initial $6,621 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a) On or about March 26th, 2026, the employer did not ensure their procedures for the control of hazardous energy for the Fury Thor Banding line down-layer table contained specific procedural steps. Specifically, the procedure did not include complete steps to isolate, relieve, and restrain stored or potential energy, for the down layer table's hydraulic/gravitational energy such as lowering the down layer table or blocking if serviced in the raised position thereby exposing maintenance employees to struck-by hazards and crushing hazards.
Recent events (2)
- — I (O) $3000
- — Z (S) $6621
1910.147 C06 II
- Issued
- Jun 5, 2026
- Abate by
- Jul 10, 2026
- Penalty
- Initial $744 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a) On or about April 1st, 2026, the employer did not properly certify the periodic inspection of the energy control procedure for the Fury Thor Banding Line. The certification record did not identify the employees included in the inspection. As a result, the employer failed to document all mandatory elements of the annual inspection certification.
Recent events (2)
- — I (O) $0
- — Z (O) $744
More inspections at Scott Steel LLC
View Scott Steel LLC's full OSHA safety record →
More inspections in this industry (NAICS 423510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348848003.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.