GENERAL DYNAMICS NASSCO

Direct exposure to electricity, unspecified · Third or fourth degree electrical burns

Federal OSHA recorded a severe workplace injury at GENERAL DYNAMICS NASSCO, m/v USS Miguel Keith, SAN DIEGO, CALIFORNIA 92113 on , Third or fourth degree electrical burns, affecting the nonclassifiable.

Watch General Dynamics Nassco for free Get an email when a new federal OSHA severe-injury report for General Dynamics Nassco is published. One employer, no account, unsubscribe in one click.

An employee was performing continuity testing on a circuit breaker. An alligator clip touched energized parts of the circuit breaker, causing an arc flash. The employee suffered second- and third-degree burns.

Hospitalized Nonclassifiable Switchboards, switches, fuses