Explosion of nonpressurized vapors, gases, or liquids · Thermal burns degree unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at American Well Service, Inc., 48 deg 000280 neg 104.153720 Storvik LW18-7-61H, FAIRVIEW, MONTANA 59221
on , Thermal burns degree unspecified, affecting the head and extremities.
Watch American Well Service, Inc. for freeGet an email when a new federal OSHA severe-injury report for American Well Service, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was using an electric torque wrench on the well when it sparked and ignited pressurized gas that was leaking from the well. This caused an explosion/flash fire that burned a nearby supervising employee's hands, arms, and face.
HospitalizedHead and extremitiesFlammable gas unspecified