Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 70,589Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

Custom Window Systems

Struck by running powered equipment n.e.c. · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at Custom Window Systems, 1900 SW 44th Ave, OCALA, FLORIDA 34471 on , Amputations, avulsions, enucleations unspecified, affecting the finger or thumb tip(s), nail(s).

Watch Custom Window Systems for free Get an email when a new federal OSHA severe-injury report for Custom Window Systems is published. One employer, no account, unsubscribe in one click.

An employee was cutting 1-inch PVC pipe on a horizontal band saw. While he was clearing the parts he had cut, a weighted handle that was pushed down to move the blade back popped up, causing the blade to strike his right thumb and hand. He suffered an amputation to the thumb tip and a laceration to the back of the right hand. The band saw was unguarded and running at the time.

Amputation Finger or thumb tip(s), nail(s) Stationary saws band

View Custom Window Systems's full OSHA safety record →