Marysville, MI ·
OSHA Injury Report: TI Fluid System - Marysville
Injury · Other recordable case
At a glance
On , an injury at TI Fluid System - Marysville in 184 Gratiot Boulevard, Marysville, MI 48040 resulted in other recordable case. Employee was maintenance Manager in brake and brake parts, automotive, truck, and bus, manufacturing.
Where did this happen?
- Establishment
- TI Fluid System - Marysville
- Parent company
- TI Fluid Systems
- Street
- 184 Gratiot Boulevard
- City
- Marysville
- State
- MI
- ZIP
- 48040
- On-site location
- Zinc Line
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Employee was investigating a dripping acid pump.
What happened
Maintenance employee and one engineering employee were completing a walk of the zinc line when the engineering employee noticed a drip coming from the acid pump when he turned it on. The engineering employee then shut the acid pump off and closed a valve to stop the drip. He called the maintenance employee over to demonstrate where the leak was. Manufacturing engineer then reactivated the pump with the maintenance manager standing back and to the right. When the pump was reactivated the pump sprayed acid on both the maintenance employee and the manufacturing engineer. Failure point was indicated to be the top of the compression fitting.
Injury or illness
Acid Burns to neck and chest.
Object or substance involved
Sulfuric Acid
Summary line
Acid Burns
Employee and industry
- Job description
- Maintenance Manager
- SOC code
- 49-1011: First-Line Supervisors of Mechanics, Installers, and Repairers
- NAICS code
- 336340: Brake and brake parts, automotive, truck, and bus, manufacturing
- NAICS vintage
- 2022
- Employees at this establishment (2024 average)
- 117
- Hours worked at this establishment (2024 total)
- 258,555
- Establishment ID
- 1169317
- Employer case #
- 2024-001
When (timing detail)
- Date of incident
- Shift started
- 07:00
- Time of incident
- 10:45
- Filing year
- 2024
- Submitted to OSHA
- 2025-01-31
More injuries at TI Fluid System - Marysville
View TI Fluid System - Marysville's full OSHA safety record →
More injuries in this industry (NAICS 336340)
More injuries in MI
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections, so no per-record IMIS deep link exists.