Denton, TX —
OSHA Injury Report: Southwire Denton Wire and Cable
Injury · Days away from work
At a glance
On , an injury at Southwire Denton Wire and Cable in Denton, TX 76208 resulted in days away from work. Employee was operator Extruder I in manufacturing.
Where did this happen?
- Establishment
- Southwire Denton Wire and Cable
- Parent company
- Southwire
- Street
- 2727 Geesling Road Denton
- City
- Denton
- State
- TX
- ZIP
- 76208
- On-site location
- Jacket Line 1
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 34
Before the incident
Tooling change at Jacket Line 1
What happened
Team Member made contact with exposed 240v wire when changing tooling at [REDACTED] extruder
Injury or illness
Nature of Injury Illness:: Electrical Shock; Body Part(s):: Hand - Whole(Right)
Object or substance involved
Exposed 240v Wire
Summary line
Nature of Injury Illness:: Electrical Shock; Cause of Injury Illness::BurnScaldContact Electric Current; Body Part(s):: Hand - Whole(Right); Object Substance:: Exposed 240v wire.
Employee and industry
- Job description
- Operator Extruder I
- SOC code
- 51-9041 — Extruding, Forming, Pressing, and Compacting Machine Setters, Operators, and Tenders
- NAICS code
- 331420 — Manufacturing
- NAICS vintage
- 2022
- Avg employees
- 270
- Total hours worked
- 609553
- Establishment ID
- 995788
- Employer case #
- US-DENTON-
When (timing detail)
- Date of incident
- Shift started
- 19:00:00.000
- Time of incident
- 2:45:00.000
- Submitted
- 01MAR24:14:47:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.