Jacksonville, FL —
OSHA Injury Report: Gate Precast Company (Jacksonville, FL)
Injury · Job transfer or restriction
At a glance
On , an injury at Gate Precast Company (Jacksonville, FL) in Jacksonville, FL 322E6 resulted in job transfer or restriction. Employee was gantry Operator in architectural wall panels, precast concrete, manufacturing.
Where did this happen?
- Establishment
- Gate Precast Company (Jacksonville, FL)
- Parent company
- Gate Petroleum
- Street
- 402 Zoo Pkwy
- City
- Jacksonville
- State
- FL
- ZIP
- 322E6
- On-site location
- Hollowcore Middle Pit
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 60
Before the incident
cleaning extruder machine
What happened
The employee wanted to show his shovel man a particular area to reach with the pressure washer and proceeded to physically point to its location by placing his arm in between the hopper and the chamfer. Unknowingly the top gantry operator turned on the hydraulic to move the extruder to the middle pit to begin the washout. In doing so the chamfer began to move slowly up pinning the operator 's right wrist
Injury or illness
crush left wrist
Object or substance involved
hollowcore extruder machine (pinch point)
Summary line
Crush right wrist
Employee and industry
- Job description
- Gantry Operator
- SOC code
- 9999 — Uncoded
- NAICS code
- 327390 — Architectural wall panels, precast concrete, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 139
- Total hours worked
- 317545
- Establishment ID
- 498702
- Employer case #
- 23-05
When (timing detail)
- Date of incident
- Shift started
- 6:00:00.000
- Time of incident
- 16:55:00.000
- Submitted
- 25JAN24:13:50:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.