PANAMA CITY, FL —
OSHA Inspection: SPURLIN INDUSTRIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SPURLIN INDUSTRIES, INC. in 700 JACKSON WAY, PANAMA CITY, FL 32405 (NAICS 000000). OSHA activity number 110131042.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPURLIN INDUSTRIES, INC.
- Site address
- 700 JACKSON WAY
- City
- PANAMA CITY
- State
- FL
- ZIP
- 32405
- Mailing
- P. O. BOX 976, PANAMA CITY, FL 32402
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3089
- Employees
- 38
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
- Penalty
- Initial $750 · Current $550 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of thermal burns from fire: a. On or about January 13, 1993, in Spray Area No. 2, the "downstream" area from the filter was not protected with a fire suppression system in the event of a fire in the exhausting area. Employees sprayed a polyester resin containing methyl ethyl ketone peroxide, (MEKP), a Class IC flammable substance, during the manufacture of fiberglass bathtub enclosures. One feasible means of control is to install an approved fire suppression system within the downstream duct area. b. On or about January 13, 1993, in Spray Area No. 1, filters were not in place to prevent the accumulation of polyester resin containing MEKP, within the exhaust duct. Employees sprayed polyester resin containing MEKP, a Class IC flammable, during the manufacture of fiberglass bathtub enclosures. One feasible means of control is to install a filter system to remove and/or catch the spray residue before its entry into the duct system.
Recent events (2)
- — I (S) $550.00
- — Z (S) $750.00
1910.95 C01
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
- Penalty
- Initial $2,500 · Current $1,875 Reduced
Recent events (2)
- — I (S) $1875.00
- — Z (S) $2500.00
1910.106 E06 II
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
- Penalty
- Initial $750 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $750.00
1910.107 F03
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
- Penalty
- Initial $750 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $750.00
1910.107 G02
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C01
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
- Penalty
- Initial $1,250 · Current $935 Reduced
Recent events (2)
- — I (S) $935.00
- — Z (S) $1250.00
1910.1030 C01 I
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
- Penalty
- Initial $1,250 · Current $935 Reduced
Recent events (2)
- — I (S) $935.00
- — Z (S) $1250.00
1910.1030 G02 VIID
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
Recent events (2)
- — I (S)
- — Z (S)
1910.38 A02
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
1910.134 B01
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
1910.1200 E01
- Issued
- May 18, 1993
- Abate by
- Jul 6, 1993
1910.107 B03
- Issued
- Feb 11, 1993
- Abate by
- Mar 16, 1993
1910.1200 E01
- Issued
- Feb 11, 1993
- Abate by
- Mar 16, 1993
More inspections at Spurlin Industries, INC.
View Spurlin Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110131042.