ERIE, PA —
OSHA Inspection: J & J CONSTRUCTION
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of J & J CONSTRUCTION in 4600 SPRINGVIEW DRIVE, ERIE, PA 16509 (NAICS 238350). OSHA activity number 122173388.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & J CONSTRUCTION
- Site address
- 4600 SPRINGVIEW DRIVE
- City
- ERIE
- State
- PA
- ZIP
- 16509
- Mailing
- 9362 EDGEWOOD LANE, WATTSBURG, PA 16442
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- SIC code (legacy)
- 1751
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Feb 29, 2008
- Abate by
- Mar 12, 2008
- Penalty
- Initial $2,000 · Current $850 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the collapse of roof trusses: (a) On or about February 14, 2008, 4600 Springview Drive, Erie, PA, Building #3; employees were exposed to the collapse of the fifty-three foot long erected roof trusses due to the following deficiencies: (1) The only lateral bracing on the erected trusses was the metal "strongties" run across the middle of the trusses. There was no lateral bracing along the top or bottom of the top chord of the trusses. (2) The diagonal bracing was inadequate in that they were installed on the top chord of the trusses running from an area near the top of the truss and run diagonally almost to the end of the truss (west to east). (3) The exterior/interior end bracing was not installed on any trusses on the building. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO ABATE THIS HAZARD IS TO FOLLOW THE RECOMMENDATIONS PROVIDED BY THE HIB-91 PAMPHLET THAT HAS BEEN INCORPORATED INTO THE BUILDING COMPONENT SAFETY INFORMATION PUBLICATION BSCI 1-03, "GUIDE TO GOOD PRACTICES FOR HANDLING, INSTALLING & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES". FOR GROUND BASE - EXTERIOR BRACING, REFERENCE SECTION B-1, PAGE 10. FOR GROUND BASE - INTERIOR BRACING, REFERENCE SECTION B-1, PAGE 11. FOR TEMPORARY TRUSS BRACING, LATERAL AND DIAGANOL BRACING, REFERENCE SECTION B-1, TABLE B1, PAGE 14.
Recent events (2)
- — I (S) $850.00
- — Z (S) $2000.00
More inspections at J & J Construction
View J & J Construction's full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 122173388.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.