CUDAHY, WI —
OSHA Inspection: LIPPMANN-MILWAUKEE, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of LIPPMANN-MILWAUKEE, INC. in 3271 EAST VAN NORMAN AVENUE, CUDAHY, WI 53110 (NAICS 333131). OSHA activity number 122420961.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LIPPMANN-MILWAUKEE, INC.
- Site address
- 3271 EAST VAN NORMAN AVENUE
- City
- CUDAHY
- State
- WI
- ZIP
- 53110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333131
- SIC code (legacy)
- 3532
- Employees
- 75
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 12, 2003
- Abate by
- Nov 18, 2003
- Penalty
- Initial $900 · Current $450 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: (a)The water heater in the East men's washroom had a shutoff valve installed between the water tank and the temperature and pressure relief valve. The water heater manufacturers' instructions, which requires a temperature and pressure relief valve installed with no other valves between it and the water tank, shall be followed. The manufacturers' instructions also requires that the temperature and pressure relief valve be installed near the top of the water heater tank so that its temperature sensing element is immersed in the water at the top of the tank. One feasible and useful method of correction would be to remove all other valves that are now between the temperature and pressure relief valve and install the temperature and pressure relief valve into the water heater. Certification, with date and method of abatement required. Certification of abatement is required by 29 CFR Part 1903 and is to be submitted within ten (10) calendar days after the abatement date.ment
Recent events (2)
- — I (S) $450.00
- — Z (S) $900.00
1910.106 D06 III
- Issued
- Nov 12, 2003
- Abate by
- Dec 1, 2003
- Penalty
- Initial $675 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $675.00
1910.106 E02 III
- Issued
- Nov 12, 2003
- Abate by
- Dec 1, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.106 E02 IVC
- Issued
- Nov 12, 2003
- Abate by
- Dec 1, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.106 E02 IVD
- Issued
- Nov 12, 2003
- Abate by
- Nov 18, 2003
- Penalty
- Initial $675 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $675.00
1910.106 E06 I
- Issued
- Nov 12, 2003
- Abate by
- Nov 18, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C04 I
- Issued
- Nov 12, 2003
- Abate by
- Nov 24, 2003
- Penalty
- Initial $1,575 · Current $1,575
Recent events (2)
- — I (S) $1575.00
- — Z (S) $1575.00
1910.303 B02
- Issued
- Nov 12, 2003
- Abate by
- Sep 17, 2003
- Penalty
- Initial $573 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $573.00
1910.304 F04
- Issued
- Nov 12, 2003
- Abate by
- Sep 17, 2003
- Penalty
- Initial $573 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $573.00
1910.305 B01
- Issued
- Nov 12, 2003
- Abate by
- Nov 18, 2003
- Penalty
- Initial $900 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $900.00
1910.219 E03 I
- Issued
- Nov 12, 2003
- Abate by
- Nov 24, 2003
Recent events (2)
- — I (O)
- — Z (O)
1926.1101 F01 I
- Issued
- Nov 12, 2003
- Abate by
- Dec 1, 2003
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 G01
- Issued
- Nov 12, 2003
- Abate by
- Nov 17, 2003
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Lippmann-Milwaukee, INC.