Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: R & R BUILDERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R & R BUILDERS in 4800 N. DIXIE HWY., BOCA RATON, FL 33441 (NAICS 000000). OSHA activity number 2306470.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & R Builders for free Get an email when a new federal OSHA severe-injury report for R & R Builders is published. One employer, no account, unsubscribe in one click.
Establishment
R & R BUILDERS
Site address
4800 N. DIXIE HWY.
City
BOCA RATON
State
FL
ZIP
33441
Mailing
P.O. BOX 627, DEERFIELD BEACH, FL 33441
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1751
Employees
10
Ownership type
Private (A)
Industry flags
Construction safety.

2 citations on file for this inspection.

5(a)(1)

Serious 1 instance 2 exposed
Issued
Apr 7, 1986
Abate by
Apr 10, 1986
Penalty
Initial $300 · Current $150 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) On March 12, 1986, employees were exposed to hazard of being struck
by falling trusses at building No. 8 at about 4800 N Dixie Highway,
Boca Raton, Florida 33432. Continuous lateral bracing across the top
and bottom chords was not installed. The special engineers
instructions on the blue prints were not carried out for bracing
piggyback trusses.
Among other methods, a feasible and acceptable abatement method would be
a) Ensure the continuous lateral bracing is installed through top and
bottom chords.
b) Follow the special engineering notes and instructions on the
blueprints.
c) Use the BWT-76, commentary and recommendations for truss erection by
the Truss Plate Institute, and ensure that it is in possession of the
erectors on site.
Recent events (2)
  • · I (S) $150.00
  • · Z (S) $300.00

1926.28 A

Serious 1 instance 2 exposed
Issued
Apr 7, 1986
Abate by
Apr 10, 1986
Penalty
Initial $300 · Current $150 Reduced
Recent events (2)
  • · I (S) $150.00
  • · Z (S) $300.00

View R & R Builders's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA's own view of this case can be found through its Establishment Search.