Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: US FISHING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of US FISHING LLC in C/P U.S.INTREPID-ALASKA SHIP DOCK, DUTCH HARBOR, AK 99692 (NAICS 000000). OSHA activity number 301496089.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Fishing LLC — free Get an email when a new federal OSHA severe-injury report for US Fishing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
US FISHING LLC
Site address
C/P U.S.INTREPID-ALASKA SHIP DOCK
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
4039 21ST AVE. WEST #201, SEATTLE, WA 98199
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2092
Employees
38
Ownership type
A
Industry flags
Maritime safety.

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 9, 2000
Abate by
Mar 28, 2000
Penalty
Initial $3,500 · Current $1,750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the potential hazard of electrocution. The following
conditions contributed to
the existence of this hazard:
a) C/P U.S.Intrepid: On the Trawl deck, a 110/120 volt electrical outlet
indicated a short in the
circuitry when tested with the IDEAL circuit tester 61-035.
b) This same electrical outlet was being used as a power source for a
vacuum cleaner which was
positioned on the wet metal deck and power to the vacuum cleaner was
obtained by using an
extension cord.
c) The extension cord was also defective, in that it was missing the
equipment grounding prong.ing
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $3500.00

1910.242 B

Serious Gravity 03 1 instance 1 exposed
Issued
Mar 9, 2000
Abate by
Mar 28, 2000
Penalty
Initial $1,125 · Current $570 Reduced
Recent events (2)
  • — I (S) $570.00
  • — Z (S) $1125.00

1915.152 A

Serious Gravity 05 1 instance
Issued
Mar 9, 2000
Abate by
Mar 28, 2000
Penalty
Initial $1,575 · Current $788 Reduced
Recent events (2)
  • — I (S) $787.50
  • — Z (S) $1575.00

1915.152 B

Serious Gravity 05 1 instance 1 exposed
Issued
Mar 9, 2000
Abate by
Mar 28, 2000
Recent events (2)
  • — I (S)
  • — Z (S)

1918.62 K04

Serious Gravity 02 2 instances 1 exposed
Issued
Mar 9, 2000
Abate by
Mar 28, 2000
Penalty
Initial $900 · Current $450 Reduced
Recent events (2)
  • — I (S) $450.00
  • — Z (S) $900.00

View US Fishing LLC's full OSHA safety record →