STONY, TX —
OSHA Inspection: NABORS DRILLING USA, LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NABORS DRILLING USA, LP in RIPPY AT REIKS STREET, STONY, TX 76259 (NAICS 213111). OSHA activity number 306201690.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NABORS DRILLING USA, LP
- Site address
- RIPPY AT REIKS STREET
- City
- STONY
- State
- TX
- ZIP
- 76259
- Mailing
- 1854 US HWY 380, BRIDGEPORT, TX 76426
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 18, 2003
- Abate by
- Jul 8, 2003
- Penalty
- Initial $1,625 · Current $1,625
General-duty citation text
Section 5(a)(1): Each employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or likely to cause death or serious physical harm to his employees. On Rig #391, wire rope clips used to hold the blow out preventer did not use the appropriate number of clips and the U-bolts were put on wrong (the U-bolts were on the live line). Also, the eye did not have a thimble. One wire rope on the drill floor was not turned back properly and the clips were not evenly spaced. The wire rope on one snub line was bird caging out of the thimble. One of the air hoses on the air hoist was split and needed to be replaced. The pipe rack did not have chocks or wedges to secure the pipe from rolling. A stairway by the pipe rack was damaged and not taken out of service or repaired. The side doors on the mud house was not properly secured to protect employees from a fall hazard. Feasible and acceptable methods to correct these hazards are: 1. Use proper rigging techniques for use of wire rope clips as outlined in 1926.251 Table H- 20. Inspect the wire rope terminations on a daily basis. 2. Replace the split air hose line. 3. Use chocks or other devices to secure pipe joints on the pipe rack. 4. Secure the side doors on the mud house.
Recent events (2)
- — I (S) $1625.00
- — Z (S) $1625.00
1910.134 K01 I
- Issued
- Jun 18, 2003
- Abate by
- Jul 8, 2003
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Nabors Drilling USA, LP
View Nabors Drilling USA, LP's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306201690.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.