OSHA Inspection: E.R. SNELL CONTRACTOR, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of E.R. SNELL CONTRACTOR, INC. in 2050 BUFORD HWY, DULUTH, GA 30097 (NAICS 237310). OSHA activity number 307834655.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch E.R. Snell Contractor, INC. for free Get an email when a new federal OSHA severe-injury report for E.R. Snell Contractor, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2050 BUFORD HWY
City
DULUTH
State
GA
ZIP
30097
Mailing
2092 SCENIC HIGHWAY, SNELLVILLE, GA 30078
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
SIC code (legacy)
1622
Employees
8
Ownership type
Private (A)

4 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 20, 2004
Abate by
Jan 18, 2005
Penalty
Initial $4,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
On or about 08/31/04, at 2050 Buford Hwy., Duluth, GA:
a) Employees were exposed to electrical shock hazards. Employer did not
notify the Utilities
Protection Center (UPC) prior to commencing work under a high voltage line
as required by
Code Section 46-3-34.
"AMONG OTHER METHODS, ONE FEASIBLE, AND ACCEPTABLE ABATEMENT
METHOD TO CORRECT THIS HAZARD IS":
1. Instruct the "person responsible for the work" to contact the Utilities
Protection Center (UPC)
as defined in paragraph (6) of Code Section 46-3-32 of the High Voltage
Safety Act.ty
Recent events (2)
  • · F (S)
  • · Z (S) $4500.00

1926.550 A15 I

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 20, 2004
Abate by
Jan 18, 2005
Penalty
Initial $4,500 · Current $500 Reduced
Recent events (2)
  • · F (S) $500.00
  • · Z (S) $4500.00

1926.550 A15 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 20, 2004
Abate by
Jan 18, 2005
Penalty
Initial $4,500 · Current $500 Reduced
Recent events (2)
  • · F (S) $500.00
  • · Z (S) $4500.00

1926.550 B02

Serious Gravity 10 4 instances 7 exposed
Issued
Dec 20, 2004
Abate by
Jan 18, 2005
Penalty
Initial $4,500 · Current $4,500
Recent events (2)
  • · F (S) $4500.00
  • · Z (S) $4500.00

View E.R. Snell Contractor, INC.'s full OSHA safety record →