Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: GRAYBAR ELECTRIC COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAYBAR ELECTRIC COMPANY, INC. in 2400 SOUTH DIVISION AVE., ORLANDO, FL 32805 (NAICS 423610). OSHA activity number 307994103.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Graybar Electric Company, INC. — free Get an email when a new federal OSHA severe-injury report for Graybar Electric Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2400 SOUTH DIVISION AVE.
City
ORLANDO
State
FL
ZIP
32805
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423610
SIC code (legacy)
5063
Employees
85
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 10 exposed
Issued
Aug 5, 2004
Abate by
Nov 4, 2004
Penalty
Initial $2,125 · Current $1,300 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that:
a. Warehouse area: Moveable shelf racks being used in the warehouse for
material
storage (a) were not anchored to the floor; and (b) did not have plaques
identifying the
rated load capacities of the racks to verify the maximum amount of
material that could
be stored safely.
Among other methods, one feasible method of abatement is to: (1) anchor
all racks
securely to the floor; and (2) install plaques indicating the rated load
capacities of the
racks in accordance with ANSI MH16.2-1984(R1996),"For the Use of
Industrial and
Commercial Steel Storage Racks - Manual of Safety Practice/A Code of Safety
Practices."
Recent events (3)
  • — P (S) $1300.00
  • — I (S) $1300.00
  • — Z (S) $2125.00

5(a)(1)

Serious Gravity 02 2 instances 10 exposed
Issued
Aug 5, 2004
Abate by
Aug 24, 2004
Penalty
Initial $1,700 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that employees were exposed to the hazard of falling from
defective ladders:
(a)Warehouse area: Fiberglass ladders in use had damaged side rails, bent
and damaged
cross bracing.  (b) Warehouse area: Fiberglass ladders were in use that
had not been
inspected.
Among other methods, one feasible method of abatement is to: 1) Provide
ladders that
meet the requirements of ANSI A14.5, Portable reinforced plastic ladders.
2) Perform
inspection and maintenance of ladders, and remove ladders from service
when damaged
as described in ANSI A14.5, Portable reinforced ladders, section 9.4.
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1700.00

1910.176 A

Serious Gravity 02 2 instances 10 exposed
Issued
Aug 5, 2004
Abate by
Sep 8, 2004
Penalty
Initial $1,700 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1700.00

1910.178 L01 I

Deleted Serious Gravity 02 10 instances 10 exposed
Issued
Aug 5, 2004
Abate by
Aug 24, 2004
Penalty
Initial $1,700
Recent events (2)
  • — I (S)
  • — Z (S) $1700.00

1910.1200 E01

Other-than-serious Gravity 01 1 instance 35 exposed
Issued
Aug 5, 2004
Abate by
Sep 8, 2004
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1200 H

Other-than-serious Gravity 01 1 instance 35 exposed
Issued
Aug 5, 2004
Abate by
Sep 8, 2004
Recent events (2)
  • — I (O)
  • — Z (O)

View Graybar Electric Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 307994103.