EVERETT, WA —
OSHA Inspection: FEDERAL AVIATION ADMINISTRATION PAINE FIELD ATCT
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FEDERAL AVIATION ADMINISTRATION PAINE FIELD ATCT in 3310 - 100TH STREET SW, EVERETT, WA 98204 (NAICS 488111). OSHA activity number 309094001.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEDERAL AVIATION ADMINISTRATION PAINE FIELD ATCT
- Site address
- 3310 - 100TH STREET SW
- City
- EVERETT
- State
- WA
- ZIP
- 98204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488111
- SIC code (legacy)
- 9621
- Employees
- 14
- Ownership type
- D
Citations
5 citations on file for this inspection.
1960.8 B
- Issued
- Nov 4, 2008
- Abate by
- Dec 23, 2008
General-duty citation text
29 CFR 1960.8(b): The head of each agency shall comply with the Occupational Safety and Health Administration standards applicable to the agency. A.On or about June 17, 2008 at the Paine Field Air Traffic Control Center facility, a written Emergency Action Plan describing the emergency procedures and/or assignments to be followed was not available at the worksite for employee review. Reference: 29 CFR 1910.38(b): An Emergency Action Plan must be in writing, kept in the workplace, and available to employees for review. Alternate Standard, G.4: The written program shall be submitted upon request to the Assistant secretary, and shall be available at the worksite for examination and copying by the Assistant Secretary, and affected employees or authorized employee representatives.
1960.8 B
- Issued
- Nov 4, 2008
- Abate by
- Dec 23, 2008
General-duty citation text
29 CFR 1960.8(b): The head of each agency shall comply with the Occupational Safety and Health Administration standards applicable to the agency. A.On or about June 17, 2008 at the Paine Field Air Traffic Control Center facility, a written Fire Prevention Plan describing the potential fire hazards, the control maintenance procedures and/or the responsible name/job assignments was not available to employees for review. Reference: 29 CFR 1910.39(b): A fire prevention plan must be in writing, kept in the workplace, and be made available to employees for review. Alternate Standard, G.4: The written program shall be submitted upon request to the Assistant secretary, and shall be available at the worksite for examination and copying by the Assistant Secretary, and affected employees or authorized employee representatives.
1960.8 A
- Issued
- Nov 4, 2008
- Abate by
- Dec 23, 2008
1960.8 B
- Issued
- Nov 4, 2008
- Abate by
- Nov 7, 2008
General-duty citation text
29 CFR 1960.8(b): The head of each agency shall comply with the Occupational Safety and Health Administration standards applicable to the agency. A.On or about June 17, 2008 in the 6th Floor Break Room/NATCO Office area, a relocatable power strip was used to provide power to a high amperage draw electrical piece of equipment (i.e. Fellows P45c shredder) contrary to the listing for the power strip. Complied with at time of inspection. Reference: 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:
1960.8 B
- Issued
- Nov 4, 2008
- Abate by
- Nov 7, 2008
General-duty citation text
29 CFR 1960.8(b): The head of each agency shall comply with the Occupational Safety and Health Administration standards applicable to the agency. A.On or about June 17, 2008 in the 10th Floor Equipment Room, access to the electrical circuit panel box identified as "EE" was blocked by a PS-52C Fellows shredder and a waste basket. Complied with at time of inspection. B.On or about June 17, 2008 in the 3rd Floor Pressurization Fan Room, access to the electrical circuit panel box identified as "SPF" was blocked by a 30-gallon garbage can. Complied with at time of inspection. Reference: 29 CFR 1910.304(e)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less were not readily accessible to each employee or authorized building management personnel: