PUEBLO, CO —
OSHA Inspection: DAVIS WIRE PUEBLO LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAVIS WIRE PUEBLO LLC in 2100 SOUTH FREEWAY, BLDG 14, PUEBLO, CO 81004 (NAICS 331222). OSHA activity number 309193050.
Where did this inspection happen?
- Establishment
- DAVIS WIRE PUEBLO LLC
- Site address
- 2100 SOUTH FREEWAY, BLDG 14
- City
- PUEBLO
- State
- CO
- ZIP
- 81004
- Mailing
- P O BOX 3250, PUEBLO, CO 81004
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331222
- SIC code (legacy)
- 3315
- Employees
- 166
- Ownership type
- A
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2500.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: a)On or about April 3, 2006, and at times prior, employees in the waste water treatment area of the plant were exposed to fall hazards where the fiberglass stepladder used to check the overflow tanks was used as a single ladder without being fully extended and the spreaders not locked in place. Among other methods, one feasible and acceptable method to correct this hazard is to train or re-train employees in the correct and proper use of step ladders. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — F (S)
- — Z (S) $2500.00
1910.23 A02
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1550.00 Reduced
Recent events (2)
- — F (S) $1550.00
- — Z (S) $2500.00
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1550.00 Reduced
Recent events (2)
- — F (S) $1550.00
- — Z (S) $2500.00
1910.106 E09 III
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1550.00
Recent events (2)
- — F (S) $1550.00
- — Z (S) $1500.00
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1550.00
Recent events (2)
- — F (S) $1550.00
- — Z (S) $1500.00
1910.212 A05
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1550.00
Recent events (2)
- — F (S) $1550.00
- — Z (S) $1500.00
1910.215 B02
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $1550.00
Recent events (2)
- — F (S) $1550.00
- — Z (S) $1500.00
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1550.00 Reduced
Recent events (2)
- — F (S) $1550.00
- — Z (S) $2500.00
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1550.00 Reduced
Recent events (2)
- — F (S) $1550.00
- — Z (S) $2500.00
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $55000.00 · Current $30000.00 Reduced
Recent events (2)
- — F (S) $30000.00
- — Z (W) $55000.00
1910.219 B01
- Issued
- Abate by
- Penalty
- Initial $40000.00 · Current $15000.00 Reduced
Recent events (2)
- — F (S) $15000.00
- — Z (W) $40000.00
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $40000.00 · Current $15000.00 Reduced
Recent events (2)
- — F (S) $15000.00
- — Z (W) $40000.00
1910.219 E01 I
- Issued
- Abate by
Recent events (2)
- — F (S)
- — Z (W)
1910.219 F01
- Issued
- Abate by
- Penalty
- Initial $55000.00 · Current $30000.00 Reduced
Recent events (2)
- — F (S) $30000.00
- — Z (W) $55000.00
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $55000.00
Recent events (2)
- — F (W)
- — Z (W) $55000.00
More inspections at DAVIS WIRE PUEBLO LLC
PUEBLO, CO—2015-05-27 00:00:00
DAVIS WIRE PUEBLO LLC
PUEBLO, CO—2012-05-04 00:00:00
DAVIS WIRE PUEBLO LLC
PUEBLO, CO—2011-12-13 00:00:00
DAVIS WIRE PUEBLO, LLC.
PUEBLO, CO—2008-05-29 00:00:00
DAVIS WIRE PUEBLO LLC
PUEBLO, CO—2008-02-25 00:00:00
DAVIS WIRE PUEBLO LLC
View DAVIS WIRE PUEBLO LLC's full OSHA safety record →
More inspections in this industry (NAICS 331222)
COMMERCE, CA—2026-07-15
WIRETECH, INC.
RURAL HALL, NC—2026-07-14
161546 - CAVERT WIRE COMPANY, LLC
VAN BUREN, AR—2026-07-08
BEKAERT CORPORATION
DICKSON, TN—2026-06-17
SUMIDEN WIRE PRODUCTS CORPORATION
WARREN, OH—2026-05-15
TRUMBULL INDUSTIRES
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309193050.