Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEED ENERGY SERVICES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LEED ENERGY SERVICES in ENCANA WELL SITE CO4, N. PICEANCE, PARACHUTE, CO 81635 (NAICS 213112). OSHA activity number 310466065.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Leed Energy Services — free Get an email when a new federal OSHA severe-injury report for Leed Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
ENCANA WELL SITE CO4, N. PICEANCE
City
PARACHUTE
State
CO
ZIP
81635
Mailing
4233 W. CENTENNIAL PARKWAY, RIFLE, CO 81650
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
4
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 4 exposed
Issued
Jun 15, 2007
Abate by
Jul 20, 2007
Penalty
Initial $5,000 · Current $3,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to struck by hazards:
a)  Leed Energy Services, EnCana well site CO4, N. Piceance, Parachute,
Colorado: The employer had not ensured that prior to pumping high pressured
water through a pipe and hose assembly into a wellbore to thaw an ice
plug, each
section of line was adequately secured to prevent unsafe movement.  On or
about
4/19/2007, an employee was seriously injured after a 20 foot long (3000 PSI
rated) section of rotary hose separated from its coupling.
The severed rotary hose was equipped with a "safety cable" rated for a
maximum
working pressure of 200 PSI.  While pumping water into the wellbore at
approximately 2900 PSI, the rotary hose failed causing a violent liquid
pressure
release and subsequent hose whipping action.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to follow the "corrective actions" section listed in the
"Safety Alert"
(#00-24 & #98-23) bulletins published by the International Association of
Drilling
Contractors (IADC) thereby ensuring that properly rated, placed, and
secured
safety clamps are utilized on all high pressure hose.
b)  Leed Energy Services, EnCana well site CO4, N. Piceance, Parachute,
Colorado:  On or about 4/19/2007, while employees of the company were using
a Gardner Denver brand tri plex pump to inject water under high pressure
into
a wellbore, a 3000 pound rated rotary hose separated from the coupling
assembly
causing a sudden release of pressure and, violent whipping action. The
pressure
relief device on the pump was set to discharge at 5000 PSI while pumping
water
through a rotary hose designed for a maximum working pressure of 3000 PSI.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to follow the American Petroleum Institute (API) Recommended
Practice 54, paragraph 9.13.6 which states the following:  Pressure relief
devices
shall be set to discharge at a pressure equal to or less than the rated
working
pressure of any pump, piping, hose, or fitting that the device is to
protect.
Abatement Note:  Abatement certification and documentation are required
for this
item (See enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $5000.00

1910.212 A01

Other-than-serious Gravity 02 3 instances 4 exposed
Issued
Jun 15, 2007
Abate by
Jun 20, 2007
Penalty
Initial $1,700 · Current $1,190 Reduced
Recent events (2)
  • — I (O) $1190.00
  • — Z (S) $1700.00

View Leed Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310466065.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.