GILCREST, CO —
OSHA Inspection: LEED ENERGY SERVICES
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of LEED ENERGY SERVICES in NEAR WCR 46 AND 29, GILCREST, CO 80623 (NAICS 213112). OSHA activity number 310468103.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEED ENERGY SERVICES
- Site address
- NEAR WCR 46 AND 29
- City
- GILCREST
- State
- CO
- ZIP
- 80623
- Mailing
- 3770 PURITAN WAY UNIT J, FREDERICK, CO 80516
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 16, 2008
- Abate by
- Feb 8, 2008
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burn hazards: a)LEED Energy Services & Rig Number 718 near 25715 WCR 51, Greeley, CO: The employer did not ensure that natural gas vapor was discharged to a safe location. On or about July 25, 2007, an employee operating the high pressure pump received fatal burn injuries as a result of the ignition of natural gas vapor. The employer installed a diesel engine pump skid with known ignition sources approximately 75 feet from the flow back tank. Among other methods, one feasible and acceptable abatement method to correct this hazard is to ensure that "Discharges of oil or gas to the atmosphere should be to a safe area, preferably on the downwind side of the well and a minimum of 100 feet (30.5 m) from the wellhead, open flame, or other sources of ignition" in accordance with American Petroleum Institute (API) RP 54, Section 12.1.8. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement Letter").
5(a)(1)
- Issued
- Jan 16, 2008
- Abate by
- Feb 8, 2008
- Penalty
- Initial $2,500 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards: a)LEED Energy Services & Rig Number 718 near 25715 WCR 51, Greeley CO: The employer had not ensured that prior to pumping high pressure fluid through a pipe and hose assembly into and out of the wellbore to clean out the well, that each section of line was adequately secured to prevent unsafe movement. This condition exposed employees to the hazard of being struck by the hose assembly in the event of a system failure. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the: "Corrective Actions" section listed in the "Safety Alert" (#00-24 & #98-23) bulletins published by the International Association of Drilling Contractors (IADC) thereby insuring that properly rated, placed, and secured safety clamps are utilized on all high pressure hose. Another possible abatement method is to follow the American Petroleum Institute (API) Recommended Practice 54, paragraph 9.13.3 which states that "Each section of high pressure rigid line should be secured using appropriate means to prevent movement should the line fail." Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement Letter").
Recent events (2)
- — I (O) $1000.00
- — Z (S) $2500.00
1910.23 D01
- Issued
- Jan 16, 2008
- Abate by
- Feb 8, 2008
More inspections at Leed Energy Services
View Leed Energy Services's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310468103.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.