Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEED ENERGY SERVICES

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of LEED ENERGY SERVICES in NEAR WCR 46 AND 29, GILCREST, CO 80623 (NAICS 213112). OSHA activity number 310468103.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Leed Energy Services — free Get an email when a new federal OSHA severe-injury report for Leed Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
NEAR WCR 46 AND 29
City
GILCREST
State
CO
ZIP
80623
Mailing
3770 PURITAN WAY UNIT J, FREDERICK, CO 80516
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
4
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 16, 2008
Abate by
Feb 8, 2008
Penalty
Initial $5,000 · Current $5,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to burn hazards:
a)LEED Energy Services & Rig Number 718 near 25715 WCR 51, Greeley, CO: The
employer did not ensure that natural gas vapor was discharged to a safe
location. On
or about July 25, 2007, an employee operating the high pressure pump
received fatal
burn injuries as a result of the ignition of natural gas vapor. The
employer installed a
diesel engine pump skid with known ignition sources approximately 75 feet
from the
flow back tank.
Among other methods, one feasible and acceptable abatement method to
correct this hazard
is to ensure that "Discharges of oil or gas to the atmosphere should be to
a safe area,
preferably on the downwind side of the well and a minimum of 100 feet
(30.5 m) from the
wellhead, open flame, or other sources of ignition" in accordance with
American Petroleum
Institute (API) RP 54, Section 12.1.8.
Abatement Note:  Abatement certification and documentation are required
for this item (See
enclosed "Sample Abatement Letter").

5(a)(1)

Other-than-serious Gravity 03 1 instance 4 exposed
Issued
Jan 16, 2008
Abate by
Feb 8, 2008
Penalty
Initial $2,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to struck by hazards:
a)LEED Energy Services & Rig Number 718 near 25715 WCR 51, Greeley CO: The
employer had not ensured that prior to pumping high pressure fluid through
a pipe
and hose assembly into and out of the wellbore to clean out the well, that
each section
of line was adequately secured to prevent unsafe movement. This condition
exposed
employees to the hazard of being struck by the hose assembly in the event
of a system
failure.
Among other methods, one feasible and acceptable abatement method to
correct this hazard
is to follow the: "Corrective Actions"  section listed in the "Safety
Alert" (#00-24 & #98-23)
bulletins published by the International Association of Drilling
Contractors (IADC) thereby
insuring that properly rated, placed, and secured safety clamps are
utilized on all high
pressure hose. Another possible abatement method is to follow the American
Petroleum
Institute (API) Recommended Practice 54, paragraph 9.13.3 which states
that "Each section
of high pressure rigid line should be secured using appropriate means to
prevent movement
should the line fail."
Abatement Note:  Abatement certification and documentation are required
for this item (See
enclosed "Sample Abatement Letter").
Recent events (2)
  • — I (O) $1000.00
  • — Z (S) $2500.00

1910.23 D01

Other-than-serious Gravity 01 1 instance 4 exposed
Issued
Jan 16, 2008
Abate by
Feb 8, 2008

View Leed Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310468103.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.