MONCURE, NC —
OSHA Inspection: ATC PANELS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ATC PANELS, INC. in 985 CORINTH ROAD, MONCURE, NC 27559 (NAICS 321219). OSHA activity number 310498696.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATC PANELS, INC.
- Site address
- 985 CORINTH ROAD
- City
- MONCURE
- State
- NC
- ZIP
- 27559
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321219
- SIC code (legacy)
- 2493
- Employees
- 110
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
95012901
- Issued
- May 2, 2007
- Abate by
- May 29, 2007
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards: a)establishment - where employee(s) were not provided operating instruction procedures for equipment such as, but not limited to, the Core Layer Dryers and the Surface Layer Dryer were exposed to explosion hazards. On or about December 2, 2006, an explosion occurred when the operator was bringing up the Core Layer Dryer (CL2). Abatement note: One feasible and acceptable abatement method, among others, to correct this hazard is to provide operating instructions which include, but not limited to, the following: a) Schematic Piping and Wiring Diagrams, b) Start-up procedures, c) Shutdown procedures, d) Emergency procedures including those occasioned by loss of special atmosphere, electric power or other essential utilities, and e) Maintenance procedures. [Reference: NFPA 86, National Fire Codes 1988: Chapter 1, Section 6.]tion
More inspections at ATC Panels, INC.
View ATC Panels, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321219)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310498696.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.