OSHA Inspection: HOLLISTER-WHITNEY ELEVATOR CORP.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of HOLLISTER-WHITNEY ELEVATOR CORP. in 2603 NORTH 24TH STREET, QUINCY, IL 62305 (NAICS 333921). OSHA activity number 310799572.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hollister-Whitney Elevator Corp. — free Get an email when a new federal OSHA severe-injury report for Hollister-Whitney Elevator Corp. is published. One employer, no account, unsubscribe in one click.
Site address
2603 NORTH 24TH STREET
City
QUINCY
State
IL
ZIP
62305
Mailing
PO BOX 4025, QUINCY, IL 62305
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333921
SIC code (legacy)
3534
Employees
226
Ownership type
A

14 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Penalty
Initial $3,500 · Current $1,700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees employment and a place of employment
which were free
from recognized hazards that were causing or were likely to cause death or
serious physical
harm to employees in that employees were exposed to:
Employees in the grinding area were exposed to fire and explosion hazards
due to explosive
aluminum dust and the employer did not ensure that the Type D Roto-Clone
Dry Centrifugal
Dust Collector was located outside the building.
Among other methods, a feasible and acceptable abatement method to correct
this
1) Eliminate the grinding process
2) Substitute the aluminum for a noncombustible material
3) Relocate the dust collection system to the outside of the building
NFPA Standard 484 - 2006 NFPA Standard 484 - 2006 Standard for Combustible
Dust,
Section 6.3.2.5: "Dry-type dust collectors shall be located outside of
buildings"
***Abatement documentation is required for this item in accordance with the
requirements of 29 CFR 1903.19(d)***
Recent events (2)
  • — I (S) $1700.00
  • — Z (S) $3500.00

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Penalty
Initial $3,500 · Current $1,700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees employment and a place of employment
which were free
from recognized hazards that were causing or were likely to cause death or
serious physical
harm to employees in that employees were exposed to:
Employees in the grinding area were exposed to fire and explosion hazards
due to the use of
polyvinyl chloride (PVC) exhaust ducting.  The ducting carried explosive
aluminum dust and
the employer did not ensure that the ducts were constructed of conductive
material.
Among other methods, a feasible and acceptable abatement method to correct
this
1) Perform a hazard analysis
2) Eliminate the grinding process
3) Substitute the aluminum for a noncombustible metal
4) Replace existing polyvinyl chloride piping with ducts that are
fabricated out of
conductive material
NFPA Standard 484 - 2006 NFPA Standard 484 - 2006 Standard for Combustible
Dust,
Section 6.3.3.5.1: "Ducts shall be constructed of conductive material and
shall be carefully
fabricated and assembled with smooth interior surfaces and with internal
lap joints facing the
direction of airflow"
***Abatement documentation is required for this item in accordance with the
requirements of 29 CFR 1903.19(d)***
Recent events (2)
  • — I (S) $1700.00
  • — Z (S) $3500.00

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Penalty
Initial $3,500 · Current $1,700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer
did not
furnish to each of his employees employment and a place of employment
which were free
from recognized hazards that were causing or were likely to cause death or
serious physical
harm to employees in that employees were exposed to:
Employees in the grinding area were exposed to fire and explosion hazards
due to explosive
aluminum dust and the employer did not ensure the ventilation system was
equipped with
deflagration venting.
Among other methods, a feasible and acceptable abatement method to correct
this
1) Perform a hazard analysis
2) Eliminate the grinding process
3) Substitute the aluminum for a noncombustible metal
4) Equip system with deflagration venting
NFPA Standard 484 - 2006 NFPA Standard 484 - 2006 Standard for Combustible
Dust,
Section 6.3.5.6: "Dry collectors used for combustible aluminum dust shall
be provided with
deflagration vents.  The selection of the type and location of vents or
weak sections of the
collector shall be designed to minimize injury to personnel and to
minimize blast and fire
damage to nearby equipment or structures"
***Abatement documentation is required for this item in accordance with the
requirements of 29 CFR 1903.19(d)***
Recent events (2)
  • — I (S) $1700.00
  • — Z (S) $3500.00

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Penalty
Initial $3,500 · Current $1,700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees employment and a place of employment
which were free
from recognized hazards that were causing or were likely to cause death or
serious physical
harm to employees in that employees were exposed to:
Employees in the grinding area were exposed to fire and explosion hazards
due
to explosive
aluminum dust and the employer did not ensure the dust from the dust
collection unit did not
recirculate into the building.
Among other methods, a feasible and acceptable abatement method to correct
this hazard is:
1) Perform a hazard analysis
2) Eliminate the grinding process
3) Substitute the aluminum for a noncombustible material
4) Vent system to the outside
NFPA Standard 484 - 2006 Standard for Combustible Dust, Section 6.3.6:
"Recycling of air
from dry dust collectors into buildings shall be prohibited"
***Abatement documentation is required for this item in accordance with the
requirements of 29 CFR 1903.19(d)***
Recent events (2)
  • — I (S) $1700.00
  • — Z (S) $3500.00

1910.22 A01

Serious Gravity 03 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 7, 2008
Penalty
Initial $1,750 · Current $800 Reduced
Recent events (2)
  • — I (S) $800.00
  • — Z (S) $1750.00

1910.132 A

Serious Gravity 03 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jun 27, 2008
Penalty
Initial $1,750 · Current $800 Reduced
Recent events (2)
  • — I (S) $800.00
  • — Z (S) $1750.00

1910.136 A

Serious Gravity 03 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jun 27, 2008

1910.212 A01

Serious Gravity 02 7 instances 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Penalty
Initial $1,400 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1400.00

1910.219 D01

Serious Gravity 02 5 instances 2 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Penalty
Initial $1,400 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1400.00

1910.219 E01 I

Serious Gravity 02 5 instances 2 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 F05 I

Serious Gravity 01 1 instance 1 exposed
Issued
Jun 3, 2008
Abate by
Jun 17, 2008
Penalty
Initial $1,050 · Current $200 Reduced
Recent events (2)
  • — I (S) $200.00
  • — Z (S) $1050.00

1910.1200 F05 II

Serious Gravity 01 1 instance 2 exposed
Issued
Jun 3, 2008
Abate by
Jun 17, 2008
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 G08

Serious Gravity 01 2 instances 1 exposed
Issued
Jun 3, 2008
Abate by
Jun 6, 2008
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 H01

Serious Gravity 01 1 instance 3 exposed
Issued
Jun 3, 2008
Abate by
Jul 21, 2008
Recent events (2)
  • — I (S)
  • — Z (S)

View Hollister-Whitney Elevator Corp.'s full OSHA safety record →