Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOLON SPECIALTY WIRE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOLON SPECIALTY WIRE in 30000 SOLON RD., SOLON, OH 44139 (NAICS 331222). OSHA activity number 313671869.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solon Specialty Wire — free Get an email when a new federal OSHA severe-injury report for Solon Specialty Wire is published. One employer, no account, unsubscribe in one click.
Site address
30000 SOLON RD.
City
SOLON
State
OH
ZIP
44139
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
SIC code (legacy)
3315
Employees
51
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 03 1 instance 51 exposed
Issued
May 3, 2010
Abate by
Jul 5, 2010
Penalty
Initial $875 · Current $875
5(a)(1): Section 5 (a)(1) of the Occupational Safety and Health Act of
1970:  The employer did not furnish
employment and a place of employment which were free from recognized
hazards that were causing or likely
to cause death or serious physical harm, including severe burns, to
employees in that employees were exposed
to dust explosion, deflagration or other hazards from dust collection
equipment located in the building:
1.The three dust collectors for the steel wire drawing lines are located
inside the building.
2.The dust collectors had no explosion venting or other explosion
prevention or suppression system.
3.No isolation device or system was installed to prevent explosions in the
dust collectors from
propagating upstream to the dust collection ducts.
Among other methods, a feasible abatement method to correct this hazard is:
Relocate the dust collectors outside the building, install relief venting
or other explosion suppression or
prevention system on the dust collectors.  Install isolation device to
prevent propagation of explosions through
duct work to employee occupied areas.  (Air passing through dust
collectors may be returned to the building if
collector has an efficiency of 99.9at 10 m.)  Installations and
modifications should be done per
requirements of the National Fire Protection Association (NFPA) 654
Standard for the Prevention of Fire and
Dust Explosions from the Manufacturing, Processing, and Handling of
Combustible Particulate Solids.
Recent events (2)
  • — F (S) $875.00
  • — Z (S) $875.00

1910.23 A03

Serious Gravity 01 1 instance 3 exposed
Issued
May 3, 2010
Abate by
Jun 5, 2011
Penalty
Initial $525 · Current $341 Reduced
Recent events (2)
  • — F (S) $341.25
  • — Z (S) $525.00

1910.212 A01

Serious Gravity 05 4 instances 48 exposed
Issued
May 3, 2010
Abate by
Jun 5, 2011
Penalty
Initial $1,225 · Current $796 Reduced
Recent events (2)
  • — F (S) $796.25
  • — Z (S) $1225.00

1910.212 A04

Serious Gravity 02 1 instance 5 exposed
Issued
May 3, 2010
Abate by
Jun 5, 2011
Penalty
Initial $700 · Current $455 Reduced
Recent events (2)
  • — F (S) $455.00
  • — Z (S) $700.00

1910.22 A02

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
May 3, 2010
Abate by
Jun 5, 2011
Recent events (2)
  • — F (O)
  • — Z (O)

1910.23 D01 III

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
May 3, 2010
Abate by
Jun 5, 2011
Recent events (2)
  • — F (O)
  • — Z (O)

1910.215 B09

Other-than-serious Gravity 01 1 instance 5 exposed
Issued
May 3, 2010
Abate by
Jun 5, 2011
Recent events (2)
  • — F (O)
  • — Z (O)

View Solon Specialty Wire's full OSHA safety record →