Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SOLVE COMPOSITES LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOLVE COMPOSITES LLC in 29 DISTRIBUTION WAY, PLATTSBURGH, NY 12901 (NAICS 326199). OSHA activity number 313761355.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solve Composites LLC for free Get an email when a new federal OSHA severe-injury report for Solve Composites LLC is published. One employer, no account, unsubscribe in one click.
Site address
29 DISTRIBUTION WAY
City
PLATTSBURGH
State
NY
ZIP
12901
Mailing
29 DISTRIBUTION WAY SUITE 101, PLATTSBURGH, NY 12901
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
SIC code (legacy)
3089
Employees
32
Ownership type
A

19 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being struck by the load:
a) Hand layout area- On or about 10/26/10- The Below-the-hook lifting
device used to
lift Resin molds had no rated load capacity markings or manufactures
markings.
Among other methods, feasible and acceptable abatement methods to correct
the hazard
are to:
1.) Inspect and test the lifting device in accordance with ASME
B30.20-1993, Section 20-
1.3, Section 20-1.4 and Section 20.4.3.
2.) Mark the rated load capacity on the device along with manufactures
name, serial
number and weigh, for the device over 100 lbs in accordance with ASME
B-30.20-1993,
Section 20-1.2.
ABATEMENT DOCUMENTATION AND CERTIFICATION IS REQUIRED FOR THIS
ITEM
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being crushed-by:
a) Hand layout area- On or about 10/26/10- An overhead carrier beam rail
in house
fabricated and welded that was used to lift molds containing resin based
materials
weighing approximately 3,000 lbs was not tested, rated or inspected.
Among other methods, several feasible and acceptable abatement methods to
correct this
hazard are to:
1. Mark the load capacity on the metal beam rail in accordance with ANSI
B30.11-1980,
Monorail Systems and Under Hung Cranes, Section 11.1 Construction and
Installation.
2.) Inspect and test the metal beam rail in accordance with ANSI
B30.11-1980, Monorail
Systems and Under Hung Cranes, Section 11.2 Inspection, Testing, and
Maintenance.
ABATEMENT DOCUMENTATION AND CERTIFICATION IS REQUIRED FOR THIS
ITEM
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that: the
employees were exposed to explosion and deflagration hazards.
a) Trim Booth Ventilation- On and before 1/11/11- Exhaust ventilation to
capture
Hazardous Air Particles (HAP) which was explosive in nature was
insufficient. The
indoor dust collector was not adequately sized, was not equipped with
explosion
protection with deflagration venting to the outside.
Among other methods, feasible and acceptable methods to correct these
hazards are:
1.) Have a qualified engineer inspect the dust collectors to evaluate the
design and installation
in accordance with National Fire Protection (NFPA) 654, Prevention of Fire
and Dust
Explosions from the Manufacturing, Processing, and Handling of Combustible
Particulate Solids
and make necessary modifications.
2.) Equip the dust collection system with explosion proof venting to the
outside of the building.
ABATEMENT DOCUMENTATION AND CERTIFICATION IS REQUIRED FOR THIS
ITEM
NFPA 654
Chapter 6 Facility and Systems Design
6.1 General. The provisions of this section shall apply to the overall
design of systems that
handle combustible particulate solids.
6.1.1* Those portions of the process and facility where a dust
deflagration hazard exists shall
be protected from the effects of dust deflagrations in accordance with
Sections 6.2, 6.3, and
6.4
Chapter 7 Process Equipment
7.1* General. Methods of fire and explosion protection for specific
equipment shall be in
accordance with this section.
Chapter 8.1.1 requires "Continuous suction to minimize the escape of dust
shall be provided for
processes where combustible dust is liberated in normal operation". The
existing dust collection
system actually maximizes the escape of dust throughout the space and Dust
Chamber. The dust
should be collected closer to the point of generation.
Chapter 8.1.2 requires "dust shall be conveyed to dust collectors". The
employer is actually
using the Trimming Booth itself to convey the dust to the Dust Chamber
collector. The room
cannot be used as a method of conveyance.
The indoor dust collector system was not adequately sized, equipped with
deflagration protection
and was not vented to the outside.
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.22 A02

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.23 D01 IV

Serious Gravity 05 1 instance 5 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $2,800 · Current $1,533 Reduced
Recent events (2)
  • · F (S) $1533.00
  • · Z (S) $2800.00

1910.24 H

Serious Gravity 05 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $3,500 · Current $1,917 Reduced
Recent events (2)
  • · F (S) $1917.00
  • · Z (S) $3500.00

1910.37 B04

Serious Gravity 05 1 instance 5 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $2,800 · Current $1,533 Reduced
Recent events (2)
  • · F (S) $1533.00
  • · Z (S) $2800.00

1910.106 H03 IIIA

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.106 H04 ID

Serious Gravity 10 2 instances 6 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.106 H07 IB

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.106 H08 I

Serious Gravity 10 3 instances 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.107 E02

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.107 E03

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.107 M01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.120 Q01

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

1910.157 G01

Serious Gravity 05 3 instances 2 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $3,500 · Current $1,917 Reduced
Recent events (2)
  • · F (S) $1917.00
  • · Z (S) $3500.00

1910.178 C02 V

Serious Gravity 05 1 instance 6 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $3,500 · Current $1,917 Reduced
Recent events (2)
  • · F (S) $1917.00
  • · Z (S) $3500.00

1910.305 G01 IVC

Serious Gravity 05 1 instance 3 exposed
Issued
Apr 4, 2011
Abate by
Apr 7, 2011
Penalty
Initial $2,800 · Current $1,533 Reduced
Recent events (2)
  • · F (S) $1533.00
  • · Z (S) $2800.00

1910.307 C

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 4, 2011
Abate by
Apr 17, 2011
Penalty
Initial $4,900 · Current $2,683 Reduced
Recent events (2)
  • · F (S) $2683.00
  • · Z (S) $4900.00

View Solve Composites LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313761355.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.