LEOLA, PA —
OSHA Inspection: SKYLINE CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SKYLINE CORPORATION in 99 HORSESHOE ROAD, LEOLA, PA 17540 (NAICS 321991). OSHA activity number 314240466.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SKYLINE CORPORATION
- Site address
- 99 HORSESHOE ROAD
- City
- LEOLA
- State
- PA
- ZIP
- 17540
- Mailing
- 99 HORSESHOE ROAD, P.O. BOX 220, LEOLA, PA 17540
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- SIC code (legacy)
- 2451
- Employees
- 126
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 5, 2010
- Abate by
- Jul 30, 2011
- Penalty
- Initial $1,875 · Current $1,315 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burn injuries from the potential dust explosion that could have resulted from, or have been exacerbated by, recycling the air back into the building without a high speed abort gate, a lack of a backflash damper and the lack of deflagration vents for the dust collector: (a)Skyline Corporation - The dust collection system was used to collect wood dust. The dust collection system, ductwork leading to the dust collector and the recycled air were not protected by a deflagration vent, a back flash damper and a high speed abort gate system in the event of a fire or explosion, on or about September 17, 2010. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard includes following the National Fire Protection Association (NFPA) 664, Standard for the Prevention of Fires and Explosion in Wood Processing and Woodworking Facilities, 2007 Edition, including, but not limited to installing a high speed abort system on the return air ductwork, installing a back flash damper, a deflagration system or a suppression system on the dust collector and/or ductwork. VERIFICATION REQUIRED
Recent events (3)
- — P (S) $1315.00
- — I (S) $1315.00
- — Z (S) $1875.00
1910.22 A01
- Issued
- Nov 5, 2010
- Abate by
- Nov 10, 2010
- Penalty
- Initial $1,875 · Current $1,310 Reduced
Recent events (2)
- — I (S) $1310.00
- — Z (S) $1875.00
More inspections at Skyline Corporation
View Skyline Corporation's full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314240466.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.