Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SKYLINE CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SKYLINE CORPORATION in 315 W. SKYLINE ROAD, ARKANSAS CITY, KS 67005 (NAICS 321991). OSHA activity number 338970932.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Skyline Corporation — free Get an email when a new federal OSHA severe-injury report for Skyline Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
SKYLINE CORPORATION
Site address
315 W. SKYLINE ROAD
City
ARKANSAS CITY
State
KS
ZIP
67005
Mailing
315 W. SKYLINE ROAD, ARKANSAS CITY, KS 67005
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321991
Employees
87
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $1,913 · Current $1,339 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Welding area - Machine guarding was not provided for the Delta Rockwell drill press to protect operators from laceration and possible amputation injuries.    29 CFR 1910.19(c)(1) abatement of the above violation was verified at the time of inspection, no certification is required.
Recent events (2)
  • — I (S) $1339.1
  • — Z (S) $1913

1910.147 C06 I

Other-than-serious 1 instance 4 exposed
Issued
Apr 5, 2013
Abate by
May 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were being  followed:    Periodic inspections of all energy control procedures were not performed for equipment such as but not limited to the shingle conveyor; the trash compactor; and the air compressor.    29 CFR 1910.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 G01 I

Other-than-serious 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(1)(i):     All 3-wire dc systems did not have their neutral conductor grounded:    Outside of the maintenance shop - The Craftsman emergency portable air compressor cord had a missing ground prong at the plug.    29 CFR 1910.19(c)(1) abatement of the above violation was verified at the time of inspection, no certification is required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Skyline Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338970932.