SAN ANTONIO, TX —
OSHA Inspection: CAPITAL CONCRETE PUMPING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAPITAL CONCRETE PUMPING in 4100 ACORN HILL, SAN ANTONIO, TX 78217 (NAICS 238910). OSHA activity number 314302936.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPITAL CONCRETE PUMPING
- Site address
- 4100 ACORN HILL
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78217
- Mailing
- 3636 EXECUTIVE CENTER DR STE 201, AUSTIN, TX 78731
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- SIC code (legacy)
- 7353
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 29, 2010
- Abate by
- Dec 3, 2010
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to flying plastic projectile hazards due to possible mechanical failure of the plastic polyvinyl chloride (PVC) piping system used to transport compress air: a) On or about 10/21/2010, employees were exposed to the hazards of flying shrapnel from an exploding plastic PVC pipe, 1/2 inch Schedule 40 PVC pipe to transport compressed throughout the mechanic shop area of the facility. The piping ran from the air compressor up to the ceiling and along the room. The compressed air was at an operating pressure of 155 pounds per square inch (PSI). Among other methods, the following are feasible and acceptable methods to correct the hazard: 1.Replace the current PVC compressed air piping system with materials suitable for the maximum air pressure as recommended by the Plastic Pipe Institute, such as ABS or metal. 2.Follow the American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.1-2007, Power Piping, as applicable. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19
Recent events (2)
- — I (S) $3080.00
- — Z (S) $3080.00
1910.132 A
- Issued
- Nov 29, 2010
- Abate by
- Dec 3, 2010
- Penalty
- Initial $3,080
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of crushing injuries associated with the rollover of a lift truck without an operator restraint system installed: a) On or about 10/21/2010, an employee was working in the mechanic shop performing maintenance on concrete pump trucks. This employee used a forklift, Model 130D-03, s/n: 351J09029230, regularly to move material. This truck had rollover protection but not seatbelt. Among other methods, feasible and acceptable abatement methods to correct this hazard are: (1) ASME B56.1-1993 Safety Standard for Low and High Lift Trucks requires the usage of an operator restraint system at all times. In the Alternative: 29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) On or about 10/21/2010, an employee was working in the mechanic shop performing maintenance on concrete pump trucks. This employee used a forklift, Model 130D-03, s/n: 351J09029230, regularly to move material. This truck had rollover protection but not seatbelt.
Recent events (2)
- — I (O)
- — Z (S) $3080.00
1910.253 B04 III
- Issued
- Nov 29, 2010
- Abate by
- Dec 3, 2010
- Penalty
- Initial $3,080 · Current $3,080
Recent events (2)
- — I (O) $3080.00
- — Z (S) $3080.00
1910.178 A06
- Issued
- Nov 29, 2010
- Abate by
- Dec 3, 2010
- Penalty
- Initial $2,310
Recent events (2)
- — I (O)
- — Z (S) $2310.00
1910.22 D01
- Issued
- Nov 29, 2010
- Abate by
- Dec 3, 2010
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Capital Concrete Pumping
View Capital Concrete Pumping's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314302936.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.