OSHA Inspection: SILVER EAGLE REFINING INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SILVER EAGLE REFINING INC. in 2990 COUNTY RD 180, EVANSTON, WY 82930 (NAICS 324110). OSHA activity number 314510710.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Silver Eagle Refining INC. — free Get an email when a new federal OSHA severe-injury report for Silver Eagle Refining INC. is published. One employer, no account, unsubscribe in one click.
Site address
2990 COUNTY RD 180
City
EVANSTON
State
WY
ZIP
82930
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
SIC code (legacy)
2911
Employees
35
Ownership type
A
Industry flags
Manufacturing health.

81 citations on file for this inspection.

1910.22 A01

Serious Gravity 05 9 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.22(a)(1) * All places of employment, passageways, storerooms, and
service rooms shall
be kept clean and orderly and in a sanitary condition.
Inadequate Housekeeping (miscellaneous boxes, drums, spare parts, etc) was
found in the
following area:  1. Maintenance Shop - Back.  2. Maintenance Shop -
Middle.  3.
Maintenance Shop - Front.  4. Outside Maintenance building.  5. Process
Unit.  6. Lab.  7.
Emergency Shower/Eye Wash areas used for storage of equipment in Process
Unit.  8.
HVAC Room.  9. Wooden floor damaged in Fire Pump building.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.23 A02

Deleted Serious Gravity 05 3 instances 3 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443
1910.23(a)(2) * Every ladderway floor opening or platform shall be guarded
by a standard
railing with standard toeboard on all exposed sides (except at entrance to
opening), with the
passage through the railing either provided with a swinging gate or so
offset that a person
cannot walk directly into the opening.
Catwalks missing end railing on process Unit and Tank Farm.  1. Tank 116
Loading Rack -
Backside.  2. DIP Rack.  3. A341 Rack.
Recent events (2)
  • — I (S)
  • — Z (S) $3443.00

1910.23 A08 II

Other-than-serious Gravity 05 6 instances 3 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.23(a)(8)(ii) * Every floor hole into which persons can accidentally
walk shall be
guarded by either: A floor hole cover of standard strength and
construction. While the cover
is not in place, the floor hole shall be constantly attended by someone or
shall be protected
by a removable standard railing.
Drains in Process Unit not adequately guarded. Approximately 6" diameter.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.26 A02 I

Other-than-serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.26(a)(2)(i) * "General specifications - straight and extension
ladders." The minimum
width between side rails of a straight ladder or any section of an
extension ladder shall be 12
inches.
Rebar ladder does not meet the minimum width requirements. 10" wide.
Recent events (2)
  • — I (O) $1148.00
  • — Z (S) $3443.00

1910.26 C02 IV

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.26(c)(2)(iv) * "Care of ladders." Ladders must be maintained in good
usable condition
at all times.
Damaged or improperly maintained ladders in Process Unit. Broken ladder
(missing foot and
half of an extension ladder) in the HDS Heater area.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.26 C02 VID

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.26(c)(2)(vi)(d) * "Care of ladders." If ladders are exposed to oil
and grease, equipment
should be cleaned of oil, grease, or slippery materials. This can easily
be done with a solvent
or steam cleaning.
Oily/dirty portable ladder in Process Unit. DIP ladder.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.28 A02

Other-than-serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443
1910.28(a)(2) * "General requirements for all scaffolds." The footing or
anchorage for
scaffolds shall be sound, rigid, and capable of carrying the maximum
intended load without
settling or displacement. Unstable objects such as barrels, boxes, loose
brick, or concrete
blocks shall not be used to support scaffolds or planks.
Scaffolding missing base plates in Catalyst Unit.
Recent events (2)
  • — I (O)
  • — Z (S) $3443.00

1910.95 G05 I

Deleted Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443
1910.95(g)(5)(i) * "Baseline audiogram." Within 6 months of an employee's
first exposure at
or above the action level, the employer shall establish a valid baseline
audiogram against
which subsequent audiograms can be compared.
Employer did not ensure that all employees had received baseline
audiograms.
Recent events (2)
  • — I (S)
  • — Z (S) $3443.00

1910.95 G06

Deleted Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.95(g)(6) * "Annual audiogram." At least annually after obtaining the
baseline
audiogram, the employer shall obtain a new audiogram for each employee
exposed at or
above an 8-hour time-weighted average of 85 decibels.
Employer did not ensure that all employees received annual audiograms.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.95 K01

Deleted Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.95(k)(1) * "Training program." The employer shall train each employee
who is exposed
to noise at or above an 8-hour time weighted average of 85 decibels in
accordance
with the
requirements of this section. The employer shall institute a training
program and ensure
employee participation in the program.
Employer did not adequately train the employees on Hearing Protection
Program. Site
specific training not accomplished.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.101 B

Serious Gravity 05 5 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.101(b) * "Compressed gases." The in-plant handling, storage, and
utilization of all
compressed gases in cylinders, portable tanks, rail tankcars, or motor
vehicle cargo tanks
shall be in accordance with Compressed Gas Association Pamphlet P-1-1965,
which is
incorporated by reference as specified in Sec. 1910.6.
Improper storage of compressed gas cylinders in facility.  1. Oxygen and
Acetylene cylinders
stored together outside of Maintenance Shop.  2. Improper storage of SCBA
cylinders in
Maintenance Shop - Back.  3. Cylinder on side in back of vehicle -
Operators
vehicle.  4.
Cylinders in Lab partially blocking access/egress door.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.106 H07 IIIC

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.106(h)(7)(iii)(c) * Locations where flammable vapor-air mixtures may
exist under
abnormal conditions and for a distance beyond Division 1 locations shall
be classified
Division 2 according to the requirements of subpart S of this part. These
locations include an
area within 20 feet horizontally, 3 feet vertically beyond a Division 1
area, and up to 3 feet
above floor or grade level within 25 feet, if indoors, or 10 feet if
outdoors, from any pump,
bleeder, withdrawal fitting, meter, or similar device handling Category 1
or 2 flammable
liquids, or Category 3 flammable liquids with a flashpoint below 100 F .
Pits provided with
adequate mechanical ventilation within a Division 1 or 2 area shall be
classified Division 2.
If Category 3 flammable liquids with a flashpoint at or above 100 F  or
Category 4
flammable liquids only are handled, then ordinary electrical equipment is
satisfactory though
care shall be used in locating electrical apparatus to prevent hot metal
from
falling into open
equipment.
Electrical equipment not maintained in intrinsically safe areas.  1. Class
I Division II
electrical boxes (2) missing bolts in Process Unit.  2. Missing cover
panels on: AC Unit in
Lab, heaters in utility closet.  3. Light cover missing in Class I
Division II location on
Process Tower in Process Unit.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.110 D10

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.110(d)(10) * Damage from vehicles. When damage to LP-Gas systems from
vehicular
traffic is a possibility, precautions against such damage shall be taken.
Outside propane tanks not protected from vehicular traffic (Lower parking
lot and by Fire
Pump building).
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.132 D01

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.132(d)(1) * Hazard assessment and equipment selection. The employer
shall assess the
workplace to determine if hazards are present, or are likely to be
present,
which necessitate
the use of personal protective equipment (PPE).
Personal Protective Equipment Hazard Assessment not completed for facility
by employer.
Recent events (2)
  • — I (O) $1148.00
  • — Z (S) $3443.00

1910.132 D02

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.132(d)(2) * The employer shall verify that the required workplace
hazard assessment
has been performed through a written certification that identifies the
workplace evaluated; the
person certifying that the evaluation has been performed; the date(s) of
the hazard
assessment; and, which identifies the document as a certification of
hazard assessment.
Personal Protective Equipment Hazard Assessment certification not
completed for facility by
employer.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.132 E

Serious Gravity 05 4 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.132(e) * Defective and damaged equipment. Defective or damaged
personal protective
equipment shall not be used.
Personal Protective Equipment not being maintained in work area.  1. Dirty
/ scratched face
shield -Maintenance Shop.  2. Broken strap on safety goggles - Maintenance
Shop.  3. Dirty
welding goggles - Maintenance Shop.  4. Dirty / damaged PPE stored in
Emergency Shower
/ Eye wash area in Process Unit.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.132 F01

Deleted Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.132(f)(1) * Training. The employer shall provide training to each
employee who is
required by this section to use PPE.
Employer did not adequately train the employees on use of Personal
Protective Equipment.
Site specific training not accomplished.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 C02

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.134(c)(2) * Respiratory protection program. This paragraph requires
the employer to
develop and implement a written respiratory protection program with
required worksite-
specific procedures and elements for required respirator use. The program
must be
administered by a suitably trained program administrator. In addition,
certain
program
elements may be required for voluntary use to prevent potential hazards
associated with the
use of the respirator. Where respirator use is not required.
Respiratory Protection program did not address where respirator use was or
was not
required.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.134 E01

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.134(e)(1) * General. The employer shall provide a medical evaluation
to determine the
employee's ability to use a respirator, before the employee is fit tested
or required to use the
respirator in the workplace. The employer may discontinue an employee's
medical
evaluations when the employee is no longer required to use a respirator.
Employer did not ensure that all employees had received a medical
evaluation for respirator
use.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.134 F02

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.134(f)(2) * The employer shall ensure that an employee using a
tight-fitting facepiece
respirator is fit tested prior to initial use of the respirator, whenever
a different respirator
facepiece (size, style, model or make) is used, and at least annually
thereafter.
Employer did not ensure that annual fit-testing of respirators for
employees were completed.
All employees expired Feb 2012.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.134 G03 III

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.134(g)(3)(iii) * Procedures for IDLH atmospheres. For all IDLH
atmospheres, the
employer shall ensure that: The employee(s) located outside the IDLH
atmosphere are trained
and equipped to provide effective emergency rescue;
Employer did not establish procedures for IDLH atmospheres. Employer did
not ensure that
employees located outside the IDLH atmosphere are trained and equipped to
provide effective
rescue.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.134 H02 I

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.134(h)(2)(i) * Storage. The employer shall ensure that respirators
are stored as follows:
All respirators shall be stored to protect them from damage,
contamination, dust, sunlight,
extreme temperatures, excessive moisture, and damaging chemicals, and they
shall be packed
or stored to prevent deformation of the facepiece and exhalation valve.
Employer did not ensure the proper storage of respirators in Maintenance
Shop - Back.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 H03 IB

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.134(h)(3)(i)(B) * Inspection. All respirators maintained for use in
emergency situations
shall be inspected at least monthly and in accordance with the
manufacturer's
recommendations, and shall be checked for proper function before and after
each use;
Employer did not ensure that airline respirator was checked at least
monthly and that it has a
low air alarm in Control Room.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 K01 I

Deleted Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.134(k)(1)(i) * The employer shall ensure that each employee can
demonstrate
knowledge of at least the following: Why the respirator is necessary and
how improper fit,
usage, or maintenance can compromise the protective effect of the
respirator;
The employer did not adequately train the employees on Respiratory
Protection Program.
Site specific training not accomplished.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.134 L01

Deleted Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.134(l)(1) * The employer shall conduct evaluations of the workplace
as necessary to
ensure that the provisions of the current written program are being
effectively
implemented
and that it continues to be effective.
Respiratory Protection program was not reviewed and/or updated regularly
by employer.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.144 A03

Other-than-serious Gravity 01 8 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $2,066
1910.144(a)(3) * Yellow. Yellow shall be the basic color for designating
caution and for
marking physical hazards such as: Striking against, stumbling, falling,
tripping, and "caught
in between."
Physical hazards such as: curbing, pipe supports, low piping, etc. was not
identified with
yellow paint or equivalent, throughout Process Unit.
Recent events (2)
  • — I (O)
  • — Z (S) $2066.00

1910.146 C02

Serious Gravity 05 10 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Mar 29, 2013
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.146(c)(2) * General requirements. If the workplace contains permit
spaces, the
employer shall inform exposed employees, by posting danger signs or by any
other equally
effective means, of the existence and location of and the danger posed by
the permit spaces.
NOTE: A sign reading DANGER -- PERMIT-REQUIRED CONFINED SPACE, DO NOT
ENTER or using other similar language would satisfy the requirement for a
sign.
Confined Space Areas not properly marked or labeled:  1. Product Storage
Tanks.  2.
Process Vessels.  3. Process Towers
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.146 D04 VIII

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.146(d)(4)(viii) * Permit-required confined space program (permit
space
program).
Under the permit space program required by paragraph (c)(4) of this
section, the employer
shall: Provide the following equipment (specified in paragraphs (d)(4)(i)
through (d)(4)(ix) of
this section) at no cost to employees, maintain that equipment properly,
and ensure that
employees use that equipment properly: Rescue and emergency equipment
needed to comply
with paragraph (d)(9) of this section, except to the extent that the
equipment is provided by
rescue services;
Emergency equipment not maintained or inspected by employer.  1. Confined
Space rescue
equipment - Maintenance Shop-Back.  2. SCBA in case in Process Unit
building.  3. Fire
hose and fittings in equipment box south of Process Unit.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D09

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.146(d)(9) * Permit-required confined space program (permit space
program). Under the
permit space program required by paragraph (c)(4) of this section, the
employer shall:
Develop and implement procedures for summoning rescue and emergency
services, for
rescuing entrants from permit spaces, for providing necessary emergency
services to rescued
employees, and for preventing unauthorized personnel from attempting a
rescue;
Employer did not develop and implement procedures for summoning rescue and
emergency
services, for rescuing entrants from confined spaces, for providing
necessary emergency
services to rescued employees, and for preventing unauthorized personnel
from attempting a
rescue.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D14

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.146(d)(14) * Permit-required confined space program (permit space
program). Under
the permit space program required by paragraph (c)(4) of this section, the
employer shall:
Review the permit space program, using the canceled permits retained under
paragraph
(e)(6)
of this section within 1 year after each entry and revise the program as
necessary, to ensure
that employees participating in entry operations are protected from permit
space hazards.
Confined Space program not reviewed and/or updated annually by employer.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.146 G01

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.146(g)(1) * Training. The employer shall provide training so that all
employees whose
work is regulated by this section acquire the understanding, knowledge,
and skills necessary
for the safe performance of the duties assigned under this section.
The employer did not adequately train the employees on Confined Space
Program. Site
specific training not accomplished.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.151 B

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443
1910.151(b) * In the absence of an infirmary, clinic, or hospital in near
proximity to the
workplace which is used for the treatment of all injured employees, a
person or persons shall
be adequately trained to render first aid. Adequate first aid supplies
shall be readily
available.
The employer did not have personnel adequately trained in first aid at the
facility.
Recent events (2)
  • — I (O)
  • — Z (S) $3443.00

1910.151 C

Other-than-serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.151(c) * Where the eyes or body of any person may be exposed to
injurious corrosive
materials, suitable facilities for quick drenching or flushing of the eyes
and body shall be
provided within the work area for immediate emergency use.
Inadequate inspection and maintenance of emergency eye wash / shower
stations.  1. No
weekly or monthly checks - Laboratory and Process Unit.  2. Showers for
decontamination
not working properly in Process Unit (Middle).  3. Inadequate emergency
eyewash / shower
for Lab personnel. Requires two valves to be opened to use.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.157 C01

Other-than-serious Gravity 01 2 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $2,066
1910.157(c)(1) * General requirements. The employer shall provide portable
fire
extinguishers and shall mount, locate and identify them so that they are
readily accessible to
employees without subjecting the employees to possible injury.
Fire extinguishers not mounted or identified.  1. Truck Loading Rack.  2.
Maintenance
Shop.
Recent events (2)
  • — I (O)
  • — Z (S) $2066.00

1910.157 C04

Deleted Serious Gravity 01 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.157(c)(4) * General requirements. The employer shall assure that
portable fire
extinguishers are maintained in a fully charged and operable condition and
kept in their
designated places at all times except during use.
Wheeled fire extinguisher (Ansul) was not adequately maintained on Process
Unit. Out of
pressure range.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.157 F05

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.157(f)(5) * Hydrostatic testing. The employer shall assure that
hydrostatic tests are
performed on extinguisher hose assemblies which are equipped with a
shut-off nozzle at the
discharge end of the hose. The test interval shall be the same as
specified for the extinguisher
on which the hose is installed.
The employer did not assure that hydrostatic tests were conducted on hose
assemblies on
Foam Trailer.
Recent events (2)
  • — I (O)
  • — Z (S)

1910.179 B05

Serious Gravity 05 3 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.179(b)(5) * General requirements - Rated load marking. The rated load
of the crane
shall be plainly marked on each side of the crane, and if the crane has
more than one
hoisting unit, each hoist shall have its rated load marked on it or its
load block and this
marking shall be clearly legible from the ground or floor.
Hoists in facility did not have rated load marked.  1. "A" frame not load
tested or marked
with load limit in Maintenance Shop.  2. "I" beam not load tested or
marked with load limit
in Knock Engine room.  3. "I" beam not load tested or marked with load
limit in Process
Unit.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.212 A01

Serious Gravity 05 15 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.212(a)(1) * Machine guarding. Types of guarding. One or more methods
of machine
guarding shall be provided to protect the operator and other employees in
the
machine area
from hazards such as those created by point of operation, ingoing nip
points, rotating parts,
flying chips and sparks. Examples of guarding methods are-barrier guards,
two-hand tripping
devices,electronic safety devices, etc.
Inadequate guarding of rotating equipment in the facility.  1. Pump shafts
not properly
guarded throughout Process Unit.  2. Pump shafts not properly guarded
throughout Product
Storage Tank area.  3. Pump shafts not properly guarded in Truck Loading
Area.  4.
Compressors not properly guarded in Process Unit.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.242 B

Serious Gravity 01 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $2,066 · Current $1,148 Reduced
1910.242(b) * Compressed air used for cleaning. Compressed air shall not
be used for
cleaning purposes except where reduced to less than 30 p.s.i. and then
only with effective
chip guarding and personal protective equipment.
Compressed air used for cleaning and improper air nozzle being used.
Airgun
not regulated
to 30 psi in Maintenance Shop.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $2066.00

1910.243 C01 IIA

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.243(c)(1)(ii)(a) * General requirements. Abrasive wheels shall be
used only on machine
provided with safety guards as defined in paragraph (c) (1) through (4) of
this section. A
safety guard shall cover the spindle end, nut and flange projections. The
safety guard shall be
mounted so as to maintain proper alignment with the wheel, and the
strength of the
fastenings shall exceed the strength of the guard.
Missing guard on angle grinder (handheld) in Maintenance Shop.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.252 A01 I

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.252(a)(1)(i) * Fire prevention and protection. Fire hazards. If the
object to be welded
or cut cannot readily be moved, all movable fire hazards in the vicinity
shall be taken to a
safe place.
Flammables / combustibles located next to welding area in Maintenance Shop.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.252 A02 IV

Deleted Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.252(a)(2)(iv) * Authorization. Before cutting or welding is
permitted, the area shall be
inspected by the individual responsible for authorizing cutting and
welding operations. He
shall designate precautions to be followed in granting authorization to
proceed preferably in
the form of a written permit.
Welding area not inspected by management for hazards in Maintenance Shop.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.253 B04 III

Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.253(b)(4)(iii) * Oxygen storage. Oxygen cylinders in storage shall be
separated from
fuel-gas cylinders or combustible materials (especially oil or grease), a
minimum distance of
20 feet or by a noncombustible barrier at least 5 feet high having a
fire-resistance rating of at
least one-half hour.
Oxygen cylinders stored near highly combustible materials (oils and
grease)
in Maintenance
Shop - Back.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.253 E03 IIC3

Deleted Serious Gravity 05 1 instance 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.253(e)(3)(ii)(C)(3) * Piping protective equipment. Flash-back
protection shall be
provided by an approved device that will prevent flame from passing into
the fuel-gas
system.
Backflow protection was not provided on gas welding equipment in
Maintenance Shop.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 B02

Serious Gravity 05 2 instances 4 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.303(b)(2) * Installation and use. Listed or labeled equipment shall
be installed and used
in accordance with any instructions included in the listing or labeling.
Incorrect use of electrical equipment.  Non UL rated power strip mounted
to workbench in
I&E Shop.ench
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.303 B07 I

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.303(b)(7)(i) * Unused openings in boxes, raceways, auxiliary gutters,
cabinets,
equipment cases, or housings shall be effectively closed to afford
protection
substantially
equivalent to the wall of the equipment.
Electrical boxes/panels missing knockouts.  1. Electrical panel on Knock
Engine. 2.
Electrical receptacle in Maintenance Shop.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 B08

Serious Gravity 05 1 instance 3 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.303(b)(8) * Electric equipment shall be firmly secured to the surface
on which it is
mounted.
Electrical outlet box not securely fastened in Fire Pump building.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 F01

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.303(f)(1) * Motors and appliances. Each disconnecting means required
by this subpart
for motors and appliances shall be legibly marked to indicate its purpose,
unless located and
arranged so the purpose is evident.
Electrical service disconnect in Maintenance Shop not marked identifying
purpose.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 F02

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.303(f)(2) * Services, feeders, and branch circuits. Each service,
feeder,
and branch
circuit, at its disconnecting means or overcurrent device, shall be
legibly marked to indicate
its purpose, unless located and arranged so the purpose is evident.
Electrical service panels not marked to identify purpose.  1. Electrical
panel Maintenance
Shop.  2. Electrical panel in Pump building.  3. Electrical panel in
Process Unit building
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 G01

Serious Gravity 05 7 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.303(g)(1) * Space about electric equipment. Sufficient access and
working space shall
be provided and maintained about all electric equipment to permit ready
and safe operation
and maintenance of such equipment.
Electrical service panels not provided with adequate space for safe
operation and
maintenance. Electrical service disconnects blocked by equipment and table
in the
Maintenance Shop.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 G02 I

Serious Gravity 05 2 instances 3 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.303(g)(2)(i) * Guarding of live parts. Except as elsewhere required
or permitted by this
standard, live parts of electric equipment operating at 50 volts or more
shall be guarded
against accidental contact by use of approved cabinets or other forms of
approved enclosures
or by any of the following means:
Electrical equipment not adequately guarded.  Electrical panel missing
cover in Fire Pump
building.l
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 A02 IX

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.305(a)(2)(ix) * All lamps for general illumination shall be protected
from accidental
contact or breakage by a suitable fixture or lampholder with a guard.
Brass shell, paper-lined
sockets, or other metal-cased sockets may not be used unless the shell is
grounded.
Bench light over drill press not protected from accidental contact or
breakage in Maintenance
Shop.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.305 A02 X

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.305(a)(2)(x) * Flexible cords and cables shall be protected from
accidental damage, as
might be caused, for example, by sharp corners, projections, and doorways
or other pinch
points.
1. Flexible cord running through metal wall in Loading Area. 2. Flexible
cord running under
roll-up door from Maintenance Shop to outside. 3. Flexible cord damaged on
cord end in
Maintenance shop.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 B01 II

Serious Gravity 05 4 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.305(b)(1)(ii) * Unused openings in cabinets, boxes, and fittings
shall be effectively
closed.
Electrical panel missing blanks. 1. Maintenance shop. 2. Fire Pump building
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 B02 I

Serious Gravity 05 10 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.305(b)(2)(i) * All pull boxes, junction boxes, and fittings shall be
provided with covers
identified for the purpose. If metal covers are used, they shall be
grounded. In completed
installations, each outlet box shall have a cover, faceplate, or fixture
canopy. Covers of
outlet boxes having holes through which flexible cord pendants pass shall
be provided with
bushings designed for the purpose or shall have smooth, well-rounded
surfaces
on which the
cords may bear.
Electrical receptacle and conduit junction boxes missing covers.
Throughout Process Unit,
Truck Loading Area, and Tank Farm
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G01 IVA

Serious Gravity 05 2 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.305(g)(1)(iv)(A) * Unless specifically permitted otherwise in
paragraph (g)(1)(ii) of this
section, flexible cords and cables may not be used: As a substitute for
the fixed wiring of a
structure;
Temporary wiring used in lieu of fixed wiring. 1. Fire Pump building. 2.
Water cooler
plugged into extension cord.  3. Knock Engine room.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G02 III

Serious Gravity 05 6 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.305(g)(2)(iii) * Flexible cords and cables shall be connected to
devices and fittings so
that strain relief is provided that will prevent pull from being directly
transmitted to joints or
terminal screws.
Inadequate strain relief provided for flexible cords. 1. Conduit to
flexible cord on pump
motors in Process Unit and Truck Loading Area. 2. Outside receptacle of
Maintenance Shop.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 E01

Other-than-serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
Penalty
Initial $2,754 · Current $1,148 Reduced
1910.1200(e)(1) * Employers shall develop, implement, and maintain at each
workplace, a
written hazard communication program which at least describes how the
criteria specified in
paragraphs (f), (g), and (h) of this section for labels and other forms of
warning, safety data
sheets, and employee information and training will be met, and which also
includes the
following:
Employer has not established a written Hazard Communication program.
Recent events (2)
  • — I (O) $1148.00
  • — Z (S) $2754.00

1910.1200 F05 I

Serious Gravity 05 4 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.1200(f)(5)(i) * Except as provided in paragraphs (f)(6) and (f)(7) of
this section, the
employer shall ensure that each container of hazardous chemicals in the
workplace is labeled,
tagged or marked with the following information: Identity of the hazardous
chemicals(s)
contained therein.
Unlabeled chemical containers / bottles: 1. Unlabeled bottles and sprayer
in Maintenance
Shop - Back. 2. Diesel fuel tank (Outside Refueling area) not labeled with
contents. 3.
Unlabeled gallon containers (Process Unit). 4. Caustic soda solution totes
not labeled.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 G08

Serious Gravity 05 3 instances 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.1200(g)(8) * The employer shall maintain in the workplace copies of
the required
material safety data sheets for each hazardous chemical, and shall ensure
that
they are readily
accessible during each work shift to employees when they are in their work
area(s).
(Electronic access, microfiche, and other alternatives to maintaining
paper copies of the
material safety data sheets are permitted as long as no barriers to
immediate employee access
in each workplace are created by such options.)
Employer did not have all MSDS for chemicals in the facility. 1. Twelve
chemicals checked,
missing three MSDS.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 H01

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1200(h)(1) * Employers shall provide employees with effective
information and training
on hazardous chemicals in their work area at the time of their initial
assignment, and
whenever a new phyical or health hazard the employees have not previously
been trained
about is introduced into their work area. Information and training may be
designed to cover
categories of hazards (e.g., flammability, carcinogenicity) or specific
chemicals. Chemical-
specific information must always be available through labels and material
safety data sheets.
The employer did not adequately train the employees on Hazard
Communication Program.
Site specific training not accomplished.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1450 E03 VII

Serious Gravity 05 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
Penalty
Initial $3,443 · Current $1,148 Reduced
1910.1450(e)(3)(vii) * Designation of personnel responsible for
implementation of the
Chemical Hygiene Plan including the assignment of a Chemical Hygiene
Officer, and, if
appropriate, establishment of a Chemical Hygiene Committee.
A Chemical Hygiene Officer and Committee were not established by employer
for the fuels
lab activities.
Recent events (2)
  • — I (S) $1148.00
  • — Z (S) $3443.00

1910.1450 E04

Serious Gravity 05 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1450(e)(4) * The employer shall review and evaluate the effectiveness
of the Chemical
Hygiene Plan at least annually and update it as necessary.
Chemical Hygiene Plan not reviewed or updated annually by employer for the
fuels lab
activities.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1450 F03 V

Deleted Serious Gravity 05 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1450(f)(3)(v) * The location and availability of known reference
material on the
hazards, safe handling, storage and disposal of hazardous chemicals found
in the laboratory
including, but not limited to, material safety Data Sheets received from
the chemical
supplier.
Ancillary: 1994 NFC 45-16 7-2.3.6, "Laboratory storage facilities shall be
inspected to
ensure compliance with the provisions of this chapter".
Improper storage of Laboratory chemicals (too many for cabinet &
incompatible substances
being stored together).
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1450 F04 IC

Serious Gravity 05 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1450(f)(4)(i)(C) * Employee training shall include: The measures
employees can take to
protect themselves from these hazards, including specific procedures the
employer has
implemented to protect employees from exposure to hazardous chemicals,
such
as appropriate
work practices, emergency procedures, and personal protective equipment to
be used.
The employer did not adequately train employees on the Chemical Hygiene
Plan for the Lab.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.22 D01

Other-than-serious 3 instances 6 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.22(d)(1) * In every building or other structure, or part thereof,
used for mercantile,
business, industrial, or storage purposes, the loads approved by the
building official shall be
marked on plates of approved design which shall be supplied and securely
affixed by the
owner of the building, or his duly authorized agent, in a conspicuous
place in each space to
which they relate. Such plates shall not be removed or defaced but, if
lost, removed, or
defaced, shall be replaced by the owner or his agent.
No load rating identified on overhead storage areas.  1. Maintenance Shop
- Back.  2.
Maintenance Shop - Middle.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.39 C01

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.39(c)(1) Minimum elements of a fire prevention plan. A fire
prevention plan must
include: A list of all major fire hazards, proper handling and storage
procedures for
hazardous materials, potential ignition sources and their control, and the
type of fire
protection equipment necessary to control each major hazard;
Fire Prevention Program missing required element, A List of Fire Hazards
at Facility.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.39 C02

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.39(c)(2) * Minimum elements of a fire prevention plan. A fire
prevention plan must
include:  Procedures to control accumulations of flammable and combustible
waste materials;
Fire Prevention Program missing required element, Control Procedures.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.39 C03

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.39(c)(3) * Minimum elements of a fire prevention plan. A fire
prevention plan must
include: Procedures for regular maintenance of safeguards installed on
heat-producing
equipment to prevent the accidental ignition of combustible materials;
Fire Prevention Program missing required element, Procedures for regular
maintenance of
safeguards installed on heat-producing equipment.cing
Recent events (2)
  • — I (O)
  • — Z (O)

1910.39 D

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.39(d) * Employee information. An employer must inform employees upon
initial
assignment to a job of the fire hazards to which they are exposed. An
employer must also
review with each employee those parts of the fire prevention plan
necessary for self-
protection.
Employer failed to inform employees upon initial Job Assignment of Fire
Hazards.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.120 Q02 II

Deleted Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.120(q)(2)(ii) * Elements of an emergency response plan. The employer
shall develop an
emergency response plan for emergencies which shall address, as a minimum,
the following
areas to the extent that they are not addressed in any specific program
required in this
paragraph: Personnel roles, lines of authority, training, and
communication.
The Emergency Response Plan was missing required element. Personnel Roles
Recent events (2)
  • — I (O)
  • — Z (O)

1910.120 Q02 V

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.120(q)(2)(v) * Elements of an emergency response plan. The employer
shall develop an
emergency response plan for emergencies which shall address, as a minimum,
the following
areas to the extent that they are not addressed in any specific program
required in this
paragraph: Site security and control.
Emergency Response Plan was missing required element. Site Security
Recent events (2)
  • — I (O)
  • — Z (O)

1910.120 Q02 XI

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.120(q)(2)(xi) * Elements of an emergency response plan. The employer
shall develop
an emergency response plan for emergencies which shall address, as a
minimum, the
following areas to the extent that they are not addressed in any specific
program required in
this paragraph: PPE and emergency equipment.
Emergency Response Plan was missing required element. Personal Protective
Equipment.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.147 C06 I

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.147(c)(6)(i) * Periodic inspection. The employer shall conduct a
periodic inspection of
the energy control procedure at least annually to ensure that the
procedure and the
requirements of this standard are being followed.
Lock out / Tag out program not reviewed or updated annually by employer.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.147 C07 IA

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.147(c)(7)(i)(A) * The employer shall provide training to ensure that
the purpose and
function of the energy control program are understood by employees and
that the knowledge
and skills required for the safe application, usage, and removal of the
energy controls are
acquired by employees. The training shall include the following: Each
authorized employee
shall receive training in the recognition of applicable hazardous energy
sources, the type and
magnitude of the energy available in the workplace, and the methods and
means necessary
for energy isolation and control.
The employer did not adequately train the employees on the Lockout / Tag
out Program. Site
specific training not accomplished.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.165 D02

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.165(d)(2) * The employer shall assure that a test of the reliability
and adequacy of non-
supervised employee alarm systems is made every two months. A different
actuation device
shall be used in each test of a multi-actuation device system so that no
individual device is
used for two consecutive tests.
Emergency alarm testing not being done at facility.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.244 A01 II

Other-than-serious 1 instance 10 exposed
Issued
Sep 13, 2012
Abate by
Sep 18, 2012
1910.244(a)(1)(ii) * The rated load shall be legibly and permanently
marked in a prominent
location on the jack by casting, stamping, or other suitable means.
Portable jack and jack stands not identified with load rating in
Maintenance shop.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1030 C01

Other-than-serious 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1030(c)(1)(i) * Each employer having an employee(s) with occupational
exposure as
defined by paragraph (b) of this section shall establish a written
Exposure
Control Plan designed
to eliminate or minimize employee exposure.
Blood borne Pathogen Program/Policy was not fully established.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1030 C01 IIB

Other-than-serious 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1030(c)(1)(ii)(B)  * The Exposure Control Plan shall contain at least
the following
elements: The schedule and method of implementation for paragraphs (d)
Methods of
Compliance, (e) HIV and HBV Research Laboratories and Production
Facilities, (f) Hepatitis
B Vaccination and Post-Exposure Evaluation and Follow-up, (g)
Communication of Hazards
to Employees, and (h) Recordkeeping, of this standard, and
The Exposure control plan was missing required element, Post-Exposure
Evaluation and
Follow-up Procedures.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1030 F01 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1030(f)(1)(i) The employer shall make available the hepatitis B
vaccine and vaccination
series to all employees who have occupational exposure, and post-exposure
evaluation and
follow-up to all employees who have had an exposure incident.
Hepatitis B Vaccination documentation was missing.
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1030 G02 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 13, 2012
Abate by
Oct 9, 2012
1910.1030(g)(2)(i) * Information and Training. The employer shall train
each employee with
occupational exposure in accordance with the requirements of this section.
Such training must
be provided at no cost to the employee and during working hours. The
employer shall
institute a training program and ensure employee participation in the
program.
The employer did not adequately train the employees on Blood Borne
Pathogen Program.
Recent events (2)
  • — I (O)
  • — Z (O)

View Silver Eagle Refining INC.'s full OSHA safety record →