OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lyondellbasell — free Get an email when a new federal OSHA severe-injury report for Lyondellbasell is published. One employer, no account, unsubscribe in one click.
Establishment
LYONDELLBASELL
Site address
2502 SHELDON ROAD
City
CHANNELVIEW
State
TX
ZIP
77530
Mailing
P.O.BOX 30, CHANNELVIEW, TX 77530
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
SIC code (legacy)
2821
Employees
500
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

1910.119 E03 VI

Deleted Serious Gravity 10 2 instances 6 exposed
Issued
Feb 22, 2011
Abate by
Mar 4, 2011
Penalty
Initial $5,000
29 CFR 1910.119(e)(3)(vi):  The process hazard analysis did not address
human factors:
ETBE Unit; the PHA did not address the following human factors during
restart of
equipment including, but not limited to, furnace F6101 following an upset
or emergency
condition.  This condition exposed employees to explosion and fire hazards:
1. Misunderstanding of radio communications
2. Confusion while restarting mutiple process equipmentg
Recent events (2)
  • — R (S)
  • — Z (S) $5000.00

1910.119 F01 I

Other-than-serious Gravity 10 1 instance 8 exposed
Issued
Feb 22, 2011
Abate by
Mar 4, 2011
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.119(f)(1):  The employer did not develop and implement written
operating
procedures that provided clear instructions for safely conducting
activities involved in startup
following a turnaround or after an emergency shutdown:
1. ETBE unit; the startup procedures for furnaces including, but not
limited to,
furnace F6101 did not address control board operator verification of pilot
on the
DSC prior to opening main gas valve.  This condition exposed employees to
explosion and fire hazards.
2.ETBE unit; the employer did not specify in the startup procedures who was
qualified and authorized to relight the furnaces including, but not
limited to,
furnace F6101.  This condition exposed employees to explosion and fire
hazards.n
Recent events (2)
  • — R (O) $5000.00
  • — Z (S) $5000.00

1910.119 F01 IV

Other-than-serious Gravity 10 1 instance 7 exposed
Issued
Feb 22, 2011
Abate by
Mar 4, 2011
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.119(f)(1)(iv):  The employer's written operating procedures
did not address
requirements for the safety systems and their functions:
ETBE unit, all functions of the furnace burner scanner bypass were not
addressed in the
operating procedures for startup of furnaces including, but not limited
to, furnace F6101,
exposing employees to explosion and fire hazards.n
Recent events (2)
  • — R (O) $5000.00
  • — Z (S) $5000.00

View Lyondellbasell's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314542929.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.