Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LYONDELLBASELL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LYONDELLBASELL in 4101 HIGHWAY 108 S, WESTLAKE, LA 70669 (NAICS 325110). OSHA activity number 346220379.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lyondellbasell — free Get an email when a new federal OSHA severe-injury report for Lyondellbasell is published. One employer, no account, unsubscribe in one click.
Establishment
LYONDELLBASELL
Site address
4101 HIGHWAY 108 S
City
WESTLAKE
State
LA
ZIP
70669
Mailing
4101 HIGHWAY 108 S, WESTLAKE, LA 70669
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325110
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.119 F04

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Feb 16, 2023
Abate by
Mar 6, 2023
Penalty
Initial $14,063 · Current $0 Reduced
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel. These safe work practices shall apply to employees and contractor employees.  On or about September 14, 2022, employees were exposed to fire, explosion, and toxic gas release hazards when the employer did not develop and implement safe work practices for opening process equipment (T-72503B) to remove/replace desiccant and to ensure the Lower Explosive Levels (LEL) of the flammable hydrocarbons.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14063

1910.147 D05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 16, 2023
Abate by
Mar 6, 2023
Penalty
Initial $0 · Current $14,063
29 CFR  1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained, or otherwise rendered safe after the application of lockout or tag-out devices to energy isolating devices.   On or about September 14, 2022, employees were exposed to hazards from residual energy in the K-line Offgas Dryer (T-72503B).
Recent events (2)
  • — I (S) $14063
  • — Z (S) $0

1910.119 H02 II

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Feb 16, 2023
Abate by
Mar 6, 2023
Penalty
Initial $14,063 · Current $0 Reduced
29 CFR  1910.119(h)(2)(ii):29 CFR 1910.119(h)(2)(ii):  The employer did not inform contract employers of potential fire, explosion or toxic release hazards related to working on or near a covered process.  On or about September 14, 2022, employees were exposed to fire, explosion, and toxic gas release hazards when the employer did not inform contract employees that the K-Line off-gas dryer vessel (T-72503B) contained flammable hydrocarbons at greater than atmospheric pressure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14063

View Lyondellbasell's full OSHA safety record →