LANGHORNE, PA ·
OSHA Inspection: SILGAN PLASTICS CORPORATION
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of SILGAN PLASTICS CORPORATION in 121 WHEELER COURT, LANGHORNE, PA 19047 (NAICS 326160). OSHA activity number 314721812.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SILGAN PLASTICS CORPORATION
- Site address
- 121 WHEELER COURT
- City
- LANGHORNE
- State
- PA
- ZIP
- 19047
- Mailing
- 121 WHEELER COURT, LANGHORNE, PA 19047
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326160
- SIC code (legacy)
- 3085
- Employees
- 110
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 13, 2012
- Abate by
- Sep 14, 2012
- Penalty
- Initial $3,825 · Current $2,678 Reduced
General-duty citation text
HAZARD: BURNS Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential explosion and fire hazards from a dust collection system located inside the building and collecting combustible dust: a) Regrind (grinding area) - On or about December 22, 2011, a dust collection system with a CP Environmental, 220 cubic foot model 84-NFB 064 C-M-G baghouse, was installed and used inside the building without devices to prevent deflagration propagation in the ductwork or explosion venting to a safe area of the building exterior. Among other methods, feasible means to abate the hazards would be to: 1. Locate the dust collection equipment outside the building 2. Ensure the dust collection system complies with generally recognized standards and guidelines such as but not limited to: NFPA 68 - Guide for venting of deflagrations NFPA 69 - Standard on Explosion Prevention Systems NFPA 654 - Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $2677.50
- · Z (S) $3825.00
1910.178 L01 I
- Issued
- Jun 13, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $3,825 · Current $3,825
Recent events (2)
- · I (S) $3825.00
- · Z (S) $3825.00
1910.178 P01
- Issued
- Jun 13, 2012
- Abate by
- Jun 18, 2012
Recent events (2)
- · I (S)
- · Z (S)
1910.303 B01
- Issued
- Jun 13, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
Recent events (2)
- · I (S) $1606.50
- · Z (S) $2295.00
1910.305 G01 IV
- Issued
- Jun 13, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
Recent events (2)
- · I (S) $1606.50
- · Z (S) $2295.00
1910.305 A02 X
- Issued
- Jun 13, 2012
- Abate by
- Jun 18, 2012
Recent events (2)
- · I (S)
- · Z (S)
1910.178 L03 IB
- Issued
- Jun 13, 2012
- Abate by
- Jun 27, 2012
- Penalty
- Initial $2,678 · Current $2,678
1910.178 L03 IJ
- Issued
- Jun 13, 2012
- Abate by
- Jun 18, 2012
1910.157 E02
- Issued
- Jun 13, 2012
- Abate by
- Jun 27, 2012
1910.305 A02 X
- Issued
- Jun 13, 2012
- Abate by
- Jun 18, 2012
More inspections at Silgan Plastics Corporation
View Silgan Plastics Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 314721812.