GOLDEN, CO —
OSHA Inspection: COORSTEK, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COORSTEK, INC. in 600 9TH ST., GOLDEN, CO 80401 (NAICS 327113). OSHA activity number 330926478.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COORSTEK, INC.
- Site address
- 600 9TH ST.
- City
- GOLDEN
- State
- CO
- ZIP
- 80401
- Mailing
- 600 9TH ST., GOLDEN, CO 80401
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327113
- Employees
- 250
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 21, 2011
- Abate by
- Dec 6, 2011
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that , employees were exposed to explosion and/or fire hazards while working near a natural gas line which had a gas leak. The natural gas pipe, valves, and hanger supports were not coated to keep them from corroding. a) On or about July 20, 2011, the employer did not ensure that employees were protected from explosion and/or fire hazards while working near a corroded natural gas line. The natural gas pipes, valves, and hanger supports were routed/located in an area where it was wet and humid, and they were not coated to prevent the metals from corrosion. Among other methods, one feasible and acceptable method to correct this hazardous condition is to ensure that the natural gas lines are coated according to ANZI Z21.30, 2.6.3 Pipe Coating, 2.9.2 Protection Against Corrosion, 2.10.3 Piping Supports.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.22 A02
- Issued
- Oct 21, 2011
- Abate by
- Feb 1, 2012
- Penalty
- Initial $4,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided when practicable. a) On or about July 21, 2011, the employer did not ensure that employees were protected from slips, trips and fall injuries while working in the waxroom area where the floors were wet and slippery.
Recent events (2)
- — I (O) $2200
- — Z (S) $4400
1910.22 A03
- Issued
- Oct 21, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(3): To facilitate cleaning, every floor, working place, and passageway shall be kept free from protruding nails, splinters, holes, or loose boards. a) On or about July 25, 2011, the employer did not ensure that employees were protected from tripping injuries while working near a concrete water ditch where the metal grade was missing. The opening was 14 inches by 6 inches, 8 inches deep.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.22 B01
- Issued
- Oct 21, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. a) On or about July 25, the employer did not ensure that employees were protected from tripping hazards while working or walking through the Wax Room Area where 4 inch pipes (diameter), 8 inches by 8 inches (L-shaped) extruding from the concrete floor.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.23 A02
- Issued
- Oct 21, 2011
- Abate by
- Nov 15, 2011
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: a) On or about July 25, 2011, the employer did not ensure that employees were protected from falls in excess of 9 feet while working from platforms in the L-95 Area and the Spray Dryer where the ladder openings did not have chains or gates.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.303 G01
- Issued
- Oct 21, 2011
- Abate by
- Dec 8, 2011
- Penalty
- Initial $4,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about July 25, 2011, the employer did not ensure that employees were protected from electrical hazards while working near and with the electrical breaker box on the 5th floor (Spray Dryer) where materials and equipment was stored in front of it.
Recent events (2)
- — I (O) $2200
- — Z (S) $4400
1910.305 E01
- Issued
- Oct 21, 2011
- Abate by
- Dec 8, 2011
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: a) On or about July 25, 2011, the employe did not ensure that employees were protected from electrical hazards while working with and near the electrical boxes (switches, breakers, cabinets etc.) in the basement where the conditions are wet and damp. The metal boxes are rusted, doors warped and do not close properly.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
More inspections at Coorstek, INC.
View Coorstek, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327113)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 330926478.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.