Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JC & SON MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JC & SON MASONRY, INC. in 1243 EDDY, CHICAGO, IL 60613 (NAICS 238140). OSHA activity number 330973850.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JC & SON Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for JC & SON Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1243 EDDY
City
CHICAGO
State
IL
ZIP
60613
Mailing
3447 N. NATCHEZ AVE., CHICAGO, IL 60634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 D16

Serious Gravity 5 1 exposed
Issued
Sep 15, 2011
Abate by
Nov 15, 2011
Penalty
Initial $3,300 · Current $1,320 Reduced
29 CFR 1926.451(d)(16): The suspension scaffold power-operated hoist or manually operated hoist did not have, in addition to the normal operating brake, a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed.    a)  Employees were working from a two-point adjustable suspension scaffold which did not have a breaking device or locking pawl.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1320
  • — Z (S) $3300

1926.451 D17

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 15, 2011
Abate by
Nov 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(17):  Manually operated hoists did not have a positive crank force to descend:    a)  Employees were working from a two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 15, 2011
Abate by
Sep 16, 2011
Penalty
Initial $3,300 · Current $1,320 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a)  Employees were not provided with safe access to a two-point adjustable suspension scaffold platform being used at an elevation of approximately 22 feet above the ground.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1320
  • — Z (S) $3300

1926.451 G01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2011
Abate by
Sep 16, 2011
Penalty
Initial $4,620 · Current $1,860 Reduced
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system:    a)  Employees were not protected from fall hazards of approximately 22 feet to the ground while working from two-point adjustable suspension scaffold.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1860
  • — Z (S) $4620

View JC & SON Masonry, INC.'s full OSHA safety record →