Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: HERNANDEZ CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HERNANDEZ CONSTRUCTION in 4341 RIVERSTONE WAY, MASON, OH 45040 (NAICS 238140). OSHA activity number 330977653.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hernandez Construction for free Get an email when a new federal OSHA severe-injury report for Hernandez Construction is published. One employer, no account, unsubscribe in one click.
Site address
4341 RIVERSTONE WAY
City
MASON
State
OH
ZIP
45040
Mailing
1818 FIREBROOK LN, CINCINNATI, OH 45240
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 F07

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 26, 2011
Abate by
Sep 29, 2011
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.451(f)(7):     Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  a) Located along the front of the residential structure, self-supproted tubular welded frame scaffolding was not erected and used properly in that a competent person did not supervise the erection process to ensure standard guardrails or personal fall arrest systems were erected or utilized.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $4200

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 26, 2011
Abate by
Sep 27, 2011
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a) Along the front of the residential structure employee(s) were observed working from self-supported tubular welded frame scaffolding which was not protected by standard guardrails or personal fall arrest systems exposing employee(s) to fall potentials in excess of 13'.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4200

View Hernandez Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 330977653.